4. Use the three screws from the accessories bag to
attach the power cord wires to the terminal block.
Refer to Figure 16.
1
1
"L1" Terminal
2
Neutral Terminal
3
"L2" Terminal
Figure 16
5. Tighten all screws firmly.
IMPORTANT: Failure to tighten these screws
firmly may result in wire failure at the terminal
block.
6. Secure the strain relief to the power cord, or
wires, where they enter the dryer cabinet.
7. Check the continuity of the ground connection
before plugging the cord into an outlet. Use an
acceptable indicating device connected to the
center grounding pin of the plug and the green
screw on the back of the cabinet.
8. Reinstall access cover and screw.
Connecting Power Cord with Four-Wire Plug
NOTE: Four-wire cord is required for new branch-
circuit installations, mobile homes or where codes
do not permit grounding through neutral.
510977
2
3
D286I
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
1
240 ± 12
V.A.C.
1
Typical Four-Wire Receptacle
2
Power Cord – Not Supplied with Dryer
3
Strain Relief Nut
4
Strain Relief
Figure 17
1. Disconnect power to dryer.
2. Remove access cover from rear of dryer.
Figure 18