Speed Queen SFET07 Installation And Operation Manual

Speed Queen SFET07 Installation And Operation Manual

Clothes dryer electric and gas models
Hide thumbs Also See for SFET07:
Table of Contents

Advertisement

Clothes Dryer
Electric and Gas Models
DRY684C
Para bajar una copia de estas instrucciones en español, visite www.comlaundry.com.
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
Part No. 510977R8
www.comlaundry.com
October 2009

Advertisement

Table of Contents
loading

Summary of Contents for Speed Queen SFET07

  • Page 1 Clothes Dryer Electric and Gas Models DRY684C Para bajar una copia de estas instrucciones en español, visite www.comlaundry.com. Keep These Instructions for Future Reference. (If this machine changes ownership, this manual must accompany machine.) Part No. 510977R8 www.comlaundry.com October 2009...
  • Page 3 IMPORTANT: Purchaser must consult the local gas supplier for suggested instructions to be followed if the dryer user smells gas. The gas utility instructions plus the SAFETY and WARNING note directly above must be posted in a prominent location near the dryer for customer use.
  • Page 4: Table Of Contents

    Exhaust Direction... 12 Exhaust System ... 13 Multi-Dryer Installation Exhaust Requirements ... 14 Step 3: (Gas Dryer Only) Connect Gas Supply Pipe ... 16 Step 4: (Electric Dryer Only) Connect Electrical Plug ... 17 Step 5: Reverse Door, if Desired ... 23 Step 6: Wipe Out Inside of Dryer ...
  • Page 5 Step 2: Load Laundry... 35 Step 3: Close Loading Door... 35 Step 4: Set Fabric Selector ... 36 Step 5: Insert Coin(s) or Card ... 36 Step 6: Start Dryer ... 36 Indicator Lights ... 37 Maintenance ... 38 Lubrication... 38 Care of Your Dryer...
  • Page 6: Safety Information

    4. Do not allow children to play on or in the dryer. Close supervision of children is necessary when the dryer is used near children. This is a safety rule for all appliances.
  • Page 7 The dryer will stop tumbling when the door is opened. Do not use the dryer if it does not stop tumbling when the door is opened or starts tumbling without pressing the START mechanism.
  • Page 8: Installation

    For maximum drying performance, we recommend that more clearance be allowed around the dryer than the clearances that are listed throughout this manual. *Electromechanical Models 39.38 in. (100 cm) *Electronic Control Models 36.94 in.
  • Page 9: Additional Security

    1-53242 Cam (30 Minutes) A 60 minute timing cam, Part No. 53240, is available for the gas dryer as optional equipment at extra cost. To change the timing cam: 1. Align notch in cam with a tooth on ratchet wheel.
  • Page 10: Coin Slide Guards

    NORMAL, PERM PRESS, DELICATE, FLUFF (no heat) Load Clothes. Insert Coin(s)/Card. To Start Dryer - Close Door and Push Start. To Stop Dryer During Cycle - Open Door. To Restart Dryer - Close Door and Push Start. Drying Cycle is Complete When Panel Light Goes Off.
  • Page 11: Before You Start

    No other fuel burning appliance should be installed in the same closet with the dryer. The dryer must not be installed or stored in an area where it will be exposed to water and/or weather. The dryer needs sufficient clearance and an adequate air supply for proper operation and ventilation, and for easier installation and servicing.
  • Page 12 Installation FRONT VIEW (w/o Closet Door) Area Dryer sides and rear clearance Dryer top clearance Dryer front clearance Exhaust duct clearance to combustible material Weather hood to ground clearance (Minimum clearances are shown.) * NOTE: For new installations, locate top of wall vent 42 inches (107 cm) above floor to make venting easier to connect.
  • Page 13: Step 2: Connect Dryer Exhaust System

    • DO NOT use plastic or thin foil ducting. Rigid metal duct is recommended. W604 W045 • Locate dryer so exhaust duct is as short as possible. • Be certain old ducts are cleaned before installing your new dryer. • Use 4 inch (10.2 cm) diameter rigid or flexible metal duct.
  • Page 14: Exhaust Direction

    © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Exhaust Direction The dryer can be exhausted to the outdoors through the back, left, right or bottom of the dryer. EXCEPTION: Gas dryers cannot be vented out the left side because of the burner housing.
  • Page 15: Exhaust System

    Exhaust System For best drying results, recommended maximum length of exhaust system is shown in Table 1. To prevent backdraft when dryer is not in operation, outer end of exhaust pipe must have a weather hood with hinged dampers (obtain locally).
  • Page 16: Multi-Dryer Installation Exhaust Requirements

    Installation Multi-Dryer Installation Exhaust Requirements Figure 7 shows a typical example of a multiple dryer installation. Note how each dryer has its own exhaust system vented to the central exhaust duct. 24" (61 cm) MINIMUM CLEARANCE TO ROOF/GROUND 58786 Backdraft Damper (Available through your local authorized parts source) Clean Out Cover must be provided.
  • Page 17 Figure 8 To reduce the risk of fire and the accumulation of combustion gases, DO NOT exhaust dryer air into a window well, gas vent, chimney or enclosed, unventilated area, such as an attic, wall, ceiling, crawl space under a building or concealed space of a building.
  • Page 18: Step 3: (Gas Dryer Only) Connect Gas Supply Pipe

    4 inch (10.2 cm) diameter VERTICAL duct system. This will prevent a backdraft when dryer is not in use, and will keep the exhaust air in balance within the central exhaust system. Step 3: (Gas Dryer Only) Connect Gas...
  • Page 19: Step 4: (Electric Dryer Only) Connect Electrical Plug

    NOTE: When connecting to a gas line, an equipment shut-off valve must be installed within 6 feet (1.8 m) of the dryer. An 1/8 in. NPT pipe plug must be installed as shown for checking inlet pressure. Refer to Figure 10.
  • Page 20 The dryer has its own terminal block that must be connected to a separate branch, 60 Hertz, single phase circuit, AC (alternating current) circuit, fused at 30 Amperes (the circuit must be fused on both sides of the line).
  • Page 21 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT THREE-WIRE CONNECTION D275I D006I FOUR-WIRE CONNECTION NOTE: Dryer is shown with access cover removed for illustration purposes only. NEVER operate the dryer with access cover removed. Ground Wire Ground to Neutral Wire Neutral Terminal “L2”...
  • Page 22 NOTE: The power cord is NOT supplied with the electric dryer. Type of power cord and gauge of wire must conform to local codes and instructions. The method of wiring the dryer is optional and subject to local code requirements.
  • Page 23 510977 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT D286I 1. Disconnect power to dryer. 2. Remove access cover from rear of dryer. Installation 240 ± 12 V.A.C. V.A.C. DRY2016N Typical Four-Wire Receptacle Power Cord –...
  • Page 24 8. Secure the strain relief to the power cord, or wires, where they enter the dryer cabinet. 9. Check the continuity of the ground connection before plugging the cord into an outlet. Use an...
  • Page 25: Step 5: Reverse Door, If Desired

    Step 5: Reverse Door, if Desired The door on this dryer is completely reversible. To reverse door proceed as follows: 1. Remove four hinge attaching screws. IN G ting at set e (he , FLU h Sta d Clo r and...
  • Page 26: Step 6: Wipe Out Inside Of Dryer

    When plugging in the dryer: • Do not overload circuits. • Do not use an adapter. • Do not use an extension cord. • Do not operate both a washer and gas dryer on the same circuit. Use separately fused 15 Amp D621I circuits.
  • Page 27: Step 8: Recheck Steps 1-7

    Do not modify the plug provided with the dryer – if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
  • Page 28 To view the burner flame, remove the lower front panel of the dryer. Close the loading door, start the dryer in a heat setting (refer to the Operation section). The dryer will start, the igniter will glow red and the main burner will ignite.
  • Page 29: Operation

    Step 2: Load Laundry Load clothes loosely into dryer drum. Add fabric softener sheet if desired. W727 Step 3: Close Loading Door Close loading door. Dryer will not operate with the door open. D625I D625I OPERATING INSTRUCTIONS Select Fabric Type (heat setting)
  • Page 30: Step 4: Set Fabric Selector

    Figure 38 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Step 5: Start Dryer Place coin(s) in slide and carefully push in as far as possible and then pull slide out as far as possible. After IN USE light comes on (indicating start of cycle), press the PUSH-TO-START button.
  • Page 31: Operation Instructions For Electronic Display Control Dryers

    Load clothes loosely into dryer drum. Add fabric softener sheet if desired. HIGH START TEMP TEMP W727 Step 3: Close Loading Door Close loading door. Dryer will not operate with the door open. D627I D627I Operation OPERATING INSTRUCTIONS Select Fabric Type (heat setting) NORMAL, PERM PRESS, DELICATE, FLUFF (no heat) Load Clothes.
  • Page 32: Step 4: Set Fabric Selector

    Do not tumble dry knit woolens. Step 6: Start Dryer To start dryer, push START pad. To stop dryer at any time, open the door. To restart the dryer, close door and push START pad. Cycle is completed when time remaining reaches 00 minutes.
  • Page 33: Indicator Lights

    PUSH START PUSH START is lit whenever the dryer is not in a cycle, the full vend price has been satisfied and the dryer door is closed. When the START pad is pressed, the cycle will begin or resume.
  • Page 34: Operation Instructions For Mdc Dryers

    Step 2: Load Laundry Load clothes loosely into dryer drum. Add fabric softener sheet if desired. W727 Step 3: Close Loading Door Close loading door. Dryer will not operate with the door open. D796I D796I OPERATING INSTRUCTIONS Select Fabric Type (heat setting)
  • Page 35: Step 4: Set Fabric Selector

    Do not tumble dry knit woolens. Step 6: Start Dryer To start dryer, push START pad. To stop dryer at any time, open the door. To restart the dryer, close door and push START pad. Cycle is completed when time remaining reaches 00 minutes.
  • Page 36: Indicator Lights

    Operation Indicator Lights START START is lit whenever the dryer is not in a cycle, the full vend price has been satisfied and the dryer door is closed. When the START pad is pressed, the cycle will begin or resume.
  • Page 37: Operation Instructions For Netmaster Dryers

    © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Step 2: Load Laundry Load clothes loosely into dryer drum. Add fabric softener sheet if desired. W727 Step 3: Close Loading Door Close loading door. Dryer will not operate with the door open. D796I D796I Operation OPERATING INSTRUCTIONS...
  • Page 38: Step 4: Set Fabric Selector

    Do not tumble dry knit woolens. Step 6: Start Dryer To start dryer, push START pad. To stop dryer at any time, open the door. To restart the dryer, close door and push START pad. Cycle is completed when time remaining reaches 00 minutes.
  • Page 39: Indicator Lights

    START START is lit whenever the dryer is not in a cycle, the full vend price has been satisfied and the dryer door is closed. When the START pad is pressed, the cycle will begin or resume.
  • Page 40: Maintenance

    To remove crayon or ball point ink off the dryer drum, put the heat on high and use old rags in the dryer to absorb the crayon or ink. If unsuccessful, contact the appliance dealer. DO NOT use any chemicals in the dryer.
  • Page 41: Motor Overload Protector

    • Use the correct temperature FABRIC SELECTOR setting for the type of fabric being dried. • Locate your dryer so the exhaust duct is as short and straight as possible. • Do not open the door during the drying cycle.
  • Page 42: Troubleshooting

    Make sure controls are in a HEAT setting. • Gas dryer only – Make sure equipment and main gas line valve is turned on. • Check exhaust duct to outside to see if it is kinked, blocked or needs cleaning.
  • Page 43: Contact Information

    If replacement parts are required, contact the source from which you purchased your dryer or contact us at (920) 748-3950 for the name and address of the nearest authorized parts distributor.
  • Page 46: Installer Checklist

    Installer Checklist Fast Track for Installing the Dryer (Refer to the manual for more detailed information) • Position and Level the Dryer. LEVEL D255I D255I CHECK • Connect Dryer Exhaust System. CHECK GAS ONLY • Connect Gas Supply Pipe. • Check for Gas Leaks.

This manual is also suitable for:

Sfgt09

Table of Contents