CHARGING SYSTI:M - Alternator
CM0o7 •
6.
REMOVE ROTOR FROM DRJVE END FRAME
Using a press and socket
wrench.
press out the rotor
spacer collars.
7.
REMOVE RECTIFIER END FRAME FROM STATOR ~lrND
RECTIFIER HOLDER
la)
Remove the
two
rubber caps.
fbl
Remove the four nuts, condense r and two insula• toors.
(cl
Remove the rectifier end -frame from the sta tor . ·
Id)
Remove the two insulators and two collars fronn
.
the
rectifier holder ~ds.
8.
UNSOLDER STATOR LEADS FROM RECTIFIER
HOLDER
CAUTION :
Protect
rectifiers
from
heat
us ing p:>l i iers
and small wattage
soldering iron. · -
INSPECTION OF ALTERNATOR
Rotor
1.
INSPECT ROTOR FOR OPEN CIRCUIT
Using an ohmmeter, check fo r continuity
between th -.ee slip
rings .
Sta ndard res istan ce:
w/
IC regulator
Approx. 2.9
a
w/o IC regulator
Approx. 4 .0
!l
If there is no continuity . replace the rotor.
2.
INSPECT THATROTOR
IS NOT GROUNDED
Using an ohmmeter, check tha t there is no continui 1
""tVf/
be-
tween the slip ring and rotor .
If there is continuity.
replace the rotor.
3.
INSPECT SLIP RINGS
Check that the slip rings are not rough
or scored .
If rough or scored, replace the rotor .