Specifications; Absolute Maximum Ratings; Esd Ratings; Recommended Operating Conditions - Texas Instruments SimpleLink CC2651R3SIPA Manual

Multiprotocol 2.4 ghz wireless system-in-package module with integrated antenna & 352-kb memory
Table of Contents

Advertisement

CC2651R3SIPA
SWRS278B – FEBRUARY 2022 – REVISED AUGUST 2023

8 Specifications

8.1 Absolute Maximum Ratings

over operating free-air temperature range (unless otherwise noted)
(3)
VDDS
Supply voltage
Voltage on any digital pin
Voltage on crystal oscillator pins, X32K_Q1, X32K_Q2
V
Voltage on ADC input
in
Input level, RF pin
T
Storage temperature
stg
(1)
Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating
Conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2)
All voltage values are with respect to ground, unless otherwise noted.
(3)
VDDS_DCDC, VDDS2 and VDDS3 must be at the same potential as VDDS.
(4)
Including analog capable DIOs.
(5)
Injection current is not supported on any GPIO pin

8.2 ESD Ratings

V
Electrostatic discharge
ESD
(1)
JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process
(2)
JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process

8.3 Recommended Operating Conditions

over operating free-air temperature range (unless otherwise noted)
(1)
Operating ambient temperature
Operating supply voltage (VDDS)
Rising supply voltage slew rate
Falling supply voltage slew rate
(1)
For thermal resistance characteristics refer to

8.4 Power Supply and Modules

over operating free-air temperature range (unless otherwise noted)
PARAMETER
VDDS Power-on-Reset (POR) threshold
VDDS Brown-out Detector (BOD)
VDDS Brown-out Detector (BOD), before initial boot
VDDS Brown-out Detector (BOD)
(1)
Brown-out Detector is trimmed at initial boot, value is kept until device is reset by a POR reset or the RESET_N pin
10
Submit Document Feedback
(4) (5)
Voltage scaling enabled
Voltage scaling disabled, internal reference
Voltage scaling disabled, VDDS as reference
Human body model (HBM), per ANSI/ESDA/JEDEC JS-001
Charged device model (CDM), per ANSI/ESDA/JEDEC JS-002
Section
8.8.
Rising threshold
(1)
Rising threshold
Falling threshold
Product Folder Links:
(1) (2)
MIN
–0.3
–0.3
–0.3
–0.3
–0.3
–0.3
–40
(1)
All pins
(2)
All pins
Copyright © 2023 Texas Instruments Incorporated
CC2651R3SIPA
www.ti.com
MAX
UNIT
4.1
V
VDDS + 0.3, max 4.1
V
VDDR + 0.3, max 2.25
V
VDDS
1.49
V
VDDS / 2.9
5
dBm
150
°C
VALUE
UNIT
±2000
V
±500
V
MIN
MAX
UNIT
–40
105
°C
1.8
3.8
V
0
100
mV/µs
0
20
mV/µs
MIN
TYP
MAX
UNIT
1.1 - 1.55
V
1.77
V
1.70
V
1.75
V

Advertisement

Table of Contents
loading

Table of Contents