Icemaker - Hoshizaki KMH-2100SRJZ Instruction Manual

Stackable crescent cuber
Table of Contents

Advertisement

1. Icemaker

Icemaker Water
Minimum Icemaker
Supply Inlet
Water Supply Line Size
1/2" Female Pipe
3/8" Nominal ID
Thread (FPT)
Copper Water Tubing or
Equivalent
• An icemaker water supply line shut-off valve and drain valve must be installed.
• Be sure there is sufficient extra water supply line and drain line for the appliance to be
pulled out for service.
Remote Condenser
Line Set Connections
Icemaker
Water Supply
Inlet
1/2" FPT
Icemaker
Drain Outlet
3/4" FPT
Ice
Storage
Vent Tube
Bin
Fig. 8
Icemaker Drain
Outlet
3/4" Female Pipe
Thread (FPT)
Icemaker
KMH-2100SRJZ/3
19
Minimum Icemaker
Drain Line Size
3/4" Nominal
ID Hard Pipe or
Equivalent
Minimum 1/2" Nominal Copper Water Tubing
Icemaker Water Supply
Line Shut-Off Valve
Condensation
Drain Outlet
3/8" OD Hard Tube
Icemaker Water Supply Line
Drain Valve
Minimum 3/4" Nominal Hard Pipe
Bin Drain Outlet
See Manufacturer's Instructions
Separate piping to approved drain.
Leave a 2-inch (5-cm) vertical air
gap between the end of each pipe
and the drain.
Vent Tube
2-inch (5-cm) air gap
Floor Drain
Condensation
Drain Outlet
3/8" OD Hard
Tube