Water-Cooled Condenser - Hoshizaki KMH-2100SRJZ Instruction Manual

Stackable crescent cuber
Table of Contents

Advertisement

2. Water-Cooled Condenser

a) Connection to an Open Drain System
Condenser Water
Minimum Condenser
Supply Inlet
Water Supply Line Size
1/2" Female Pipe
3/8" Nominal ID Copper
Thread (FPT)
Water Tubing or Equivalent
• A condenser water supply line shut-off valve and drain valve must be installed.
• In some areas, a back flow preventer may be required in the cooling water circuit.
• In order to maintain the proper high side pressure, the condenser water supply inlet
temperature should not drop below 45°F (7°C) and the condenser drain outlet temperature
must be in the 104°F to 115°F (40°C to 46°C) range. Once the icemaker installation
is complete, confirm the condenser drain outlet temperature 5 minutes after a freeze
cycle starts. If the condenser drain outlet temperature is not in the proper range, use a
flat blade screwdriver to rotate the adjustment screw on the water-regulating valve until
the temperature is in the proper range (rotate counterclockwise to raise temperature or
clockwise to lower temperature).
Vent Tube
Condenser
Drain Outlet
3/8" FPT
Icemaker
Water Supply
Inlet
1/2" FPT
Condenser Water
Supply Inlet
1/2" FPT
Minimum 3/8"
Nominal Hard
Pipe
Icemaker
Drain Outlet
3/4" FPT
Ice
Storage
Vent Tube
Bin
Fig. 9
Connection to an Open Drain System
Icemaker
Condensation
Drain Outlet
3/8" OD Hard Tube
KMH-2100SWJ3
Condenser Drain
Minimum Condenser
Outlet
Drain Line Size
3/8" Female Pipe
3/8" Nominal ID Hard Pipe
Thread (FPT)
or Equivalent
Minimum 3/8" Nominal Copper Water Tubing
Minimum 1/2" Nominal Copper Water Tubing
Icemaker Water Supply Line
Shut-Off Valve
Condenser Water Supply Line
Drain Valve
Icemaker Water Supply Line
Drain Valve
Minimum 3/4" Nominal Hard Pipe
Bin Drain Outlet
See Manufacturer's Instructions
Separate piping to approved drain.
Leave a 2-inch (5-cm) vertical air
gap between the end of each pipe
and the drain.
Vent Tube
20
Condenser Water Supply Line
Shut-Off Valve
2-inch (5-cm) air gap
Floor Drain

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kmh-2100swj3Kmh-2100srjz3

Table of Contents