Btuh For Low-Heat Per Burner, Derated 4 Percent For Each 1000 Ft.(305 M) Above Sea Level) - Carrier 58TP0B Installation, Start-Up, Operating And Service And Maintenance Instructions

Table of Contents

Advertisement

58TP0B/58TP1B: Installation, Start-up, Operating and Service and Maintenance Instructions
Table 17 – Orifice Size and Manifold Pressure (in. w.c.) for Gas Input Rate (Tabulated Data Based on 22,000 BTUh High-Heat/14,500 BTUh
for Low-Heat per Burner, Derated 4 Percent for Each 1000 Ft.(305 M) Above Sea Level) (Continued)
AVG. GAS HEAT
ALTITUDE RANGE
VALUE AT
FT. (M)
ALTITUDE
(BTUH/CU FT.)
7001 to
8000
USA
(2134 to
2438)
8001 to
9000
USA
(2438 to
2743)
9001 to
10,000
USA
2743 to
3048)
* Orifice numbers 43 are factory installed
Table 18 – Orifice Size and Manifold Pressure (in. w.c.) for Gas Input Rate (Tabulated Data Based on 21,000 BTUh High-Heat/14,500 BTUh
for Low-Heat per Burner, Derated 4 Percent for Each 1000 Ft.(305 M) Above Sea Level)
AVG. GAS
ALTITUDE RANGE
VALUE
FT. (M)
(BTUH/CU
0 to 2000
USA
(0 to 610)
2001 to
USA
3000 (610
to 914)
3001 to
USA
4000 (914
to 1219)
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
0.58
Manifold
Orifice No.
Pressure
High/Low
650
44
3.6/1.6
675
44
3.3/1.5
700
45
3.8/1.6
725
46
3.7/1.6
750
46
3.4/1.5
775
47
3.6/1.6
800
47
3.4/1.5
825
48
3.7/1.6
625
44
3.3/1.5
650
45
3.7/1.6
675
46
3.6/1.6
700
47
3.8/1.7
725
47
3.6/1.6
750
48
3.8/1.7
775
48
3.6/1.5
600
45
3.7/1.6
625
46
3.6/1.6
650
47
3.8/1.6
675
47
3.5/1.5
700
48
3.7/1.6
725
48
3.5/1.5
HEAT
0.58
Manifold
Orifice No.
Pressure
FT.)
High/Low
900
42
3.2/1.5
925
43
3.7/1.8
950
43
3.5/1.7
975
43
3.3/1.6
1000
44
3.6/1.7
1025
44
3.4/1.6
1050
44
3.3/1.6
1075
45
3.8/1.8
1100
46
3.8/1.8
800
43
3.8/1.8
825
43
3.5/1.7
850
43
3.3/1.6
875
43
3.2/1.5
900
44
3.4/1.6
925
44
3.2/1.5
950
45
3.7/1.8
975
46
3.7/1.8
1000
46
3.5/1.7
775
43
3.5/1.7
800
43
3.3/1.6
825
44
3.6/1.7
850
44
3.4/1.6
875
45
3.8/1.8
900
46
3.8/1.8
925
46
3.6/1.7
950
46
3.4/1.6
SPECIFIC GRAVITY OF NATURAL GAS
0.60
Manifold
Orifice No.
Pressure
Orifice No.
High/Low
43
3.2/1.4
44
3.5/1.5
44
3.2/1.4
46
3.8/1.7
46
3.6/1.5
47
3.8/1.6
47
3.5/1.5
48
3.8/1.6
44
3.5/1.5
44
3.2/1.4
46
3.8/1.6
46
3.5/1.5
47
3.7/1.6
47
3.5/1.5
48
3.7/1.6
45
3.8/1.7
46
3.7/1.6
46
3.4/1.5
47
3.6/1.6
48
3.8/1.7
48
3.6/1.6
SPECIFIC GRAVITY OF NATURAL GAS
0.60
Manifold
Orifice No.
Pressure
Orifice No.
High/Low
42
3.3/1.6
43
3.8/1.8
43
3.6/1.7
43
3.4/1.6
43
3.3/1.6
44
3.6/1.7
44
3.4/1.6
44
3.2/1.5
45
3.7/1.8
42
3.2/1.5
43
3.7/1.7
43
3.5/1.6
43
3.3/1.6
44
3.5/1.7
44
3.3/1.6
45
3.8/1.8
46
3.8/1.8
46
3.6/1.7
43
3.7/1.7
43
3.4/1.6
43
3.2/1.5
44
3.5/1.7
44
3.3/1.6
45
3.8/1.8
46
3.7/1.8
46
3.5/1.7
37
0.62
Manifold
Pressure
Orifice No.
High/Low
43
3.4/1.5
43
44
3.6/1.6
43
44
3.3/1.4
44
45
3.7/1.6
44
46
3.7/1.6
46
46
3.4/1.5
46
47
3.7/1.6
47
47
3.4/1.5
47
44
3.6/1.6
43
44
3.3/1.4
44
45
3.7/1.6
45
46
3.6/1.6
46
47
3.8/1.7
46
47
3.6/1.6
47
48
3.8/1.7
47
44
3.3/1.4
44
46
3.8/1.7
45
46
3.6/1.5
46
47
3.7/1.6
46
47
3.5/1.5
47
48
3.7/1.6
48
0.62
Manifold
Pressure
Orifice No.
High/Low
42
3.4/1.6
42
42
3.2/1.5
42
43
3.7/1.8
43
43
3.5/1.7
43
43
3.4/1.6
43
43
3.2/1.5
43
44
3.5/1.7
43
44
3.3/1.6
44
44
3.2/1.5
44
42
3.3/1.6
42
43
3.8/1.8
42
43
3.6/1.7
43
43
3.4/1.6
43
43
3.2/1.5
43
44
3.5/1.6
44
44
3.3/1.6
44
45
3.8/1.8
44
46
3.8/1.8
45
43
3.8/1.8
42
43
3.5/1.7
43
43
3.3/1.6
43
44
3.6/1.7
43
44
3.4/1.6
44
44
3.2/1.5
44
45
3.7/1.8
45
46
3.7/1.7
46
0.64
Manifold
Pressure
High/Low
3.5/1.5
3.2/1.4
3.4/1.5
3.2/1.4
3.8/1.6
3.6/1.5
3.8/1.6
3.6/1.5
3.2/1.4
3.4/1.5
3.8/1.7
3.7/1.6
3.5/1.5
3.7/1.6
3.5/1.5
3.4/1.5
3.8/1.6
3.7/1.6
3.4/1.5
3.6/1.6
3.8/1.7
0.64
Manifold
Pressure
High/Low
3.5/1.7
3.3/1.6
3.8/1.8
3.7/1.7
3.5/1.7
3.3/1.6
3.2/1.5
3.4/1.6
3.3/1.6
3.4/1.6
3.2/1.5
3.7/1.8
3.5/1.7
3.3/1.6
3.6/1.7
3.4/1.6
3.2/1.5
3.7/1.8
3.2/1.5
3.7/1.7
3.4/1.6
3.2/1.5
3.5/1.7
3.3/1.6
3.8/1.8
3.8/1.8

Advertisement

Table of Contents
loading

This manual is also suitable for:

58tp1b

Table of Contents