LG 55QNED85SQA Service Manual page 68

Chassis : ub22a
Hide thumbs Also See for 55QNED85SQA:
Table of Contents

Advertisement

Standard Repair Process Detail Technical Manual
symptom
Content
IR & EYE Sensor
Eye LED
Checking order to check remote control
Checking order
1. Check IR cable condition between IR & Main board.(Check picture number① and ②.)
2. Check the standby 3.5V on the terminal. (③)
Error
D. Function error
Remote control operation checking method
IR
Pin #25
Pin #1
Established
date
Revised
date
A14
A14
Pin
Pin name
1
+3.5V_WIFI
2
WIFI_DM
3
WIFI_DP
4
GND
5
WOL/WIFI_POWER_ON
6
+3.5V_WIFI
7
WIFI_SUSPEND/RESUME
8
GND
9
COMBO_RESET
10
BT_WAKEUP_HOST
11
GND
12
+3.5V_WIFI
13
N.C
14
N.C
15
N.C
16
EYE_SDA
17
EYE_SCL
18
GND
19
IR
20
LED_R
21
GND
22
+3.5V_ST
23
KEY2
24
MIC_DATA
25
MIC_CLK

Advertisement