SMC Networks ISE70 AB Series Operation Manual page 66

High-precision digital pressure switch
Hide thumbs Also See for ISE70 AB Series:
Table of Contents

Advertisement

○Error indication function
This function is to display error location and content when a problem or error has occurred.
Error
Error displayed
Over current
error
Residual
pressure error
Pressurizing
error
System error
If the error cannot be reset after the above measures are taken, or errors other than above are displayed,
please contact SMC.
Description
The load current applied to the switch
output has exceeded the maximum
value.
During zero clear operation, pressure
greater than ±7% F.S. is present. Note
that the mode is returned to
measurement mode automatically
1 second later. The zero clear range
varies by ±1% F.S. due to variation
between individual products.
Pressure exceeding the upper limit of
the set pressure range is applied.
Pressure exceeding the lower limit of
the set pressure range is applied.
Displayed if an internal data error has
occurred.
-65-
Measures
Turn the power off and remove the
cause of the over current.
Then supply the power again.
Release the applied pressure to
atmospheric pressure, and retry
the zero clear operation.
Reset applied pressure to a level
within the set pressure range.
Turn the power off and on again.
If the failure cannot be solved,
contact SMC.
No.PS※※-OMW0002-D

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ise71 ab seriesIse70Ise71

Table of Contents