7.
From Platform, pull Power/Emergency Stop switch out.
8.
Push the Engine Start switch until engine starts.
Note: Footswitch must be released in the up position before starter will operate. If
starter operates with footswitch in the down position, do not operate the
machine.
4.5.2
Shutdown Procedure
If an engine malfunction causes an unscheduled shutdown, determine the cause
and correct it before restarting the engine.
1.
Remove all load and allow engine to operate at low speed for 3-5
minutes; this allows further reduction of internal engine temperature.
2.
Push Power/Emergency Stop switch in.
3.
Turn Platform/Ground Select switch to Off.
Note: Refer to Engine Manufacturer's manual for detailed information.