General Specifications and Operator Maintenance
4.
Wheel Drive Hub
Lube Point(s) - Level/Fill Plug
Capacity - 0.5 quarts (0.5 liters) ± 10%
Lube - EPGL
Interval - Change after first 150 hours then every 1200 hours of operation
Comments - Place Fill port at 12 o'clock position and Check port at 3 o'clock
position. Pour lubricant into fill port until it just starts to flow out of check port.
5. Hydraulic Return Filter
Lube Point(s) - Replaceable Element
Interval - Change after first 50 hours and every 300 hours thereafter or as
indicated by condition indicator.
138
31222384
BM000229A
BM000230A
1250AJP