National Instruments NI 6583R User Manual And Specifications page 21

Table of Contents

Advertisement

17. Select NI 6583 Voltage Level. Click OK to drag and place the file on your block diagram.
18. Right-click the Voltage Level control and select Change to Control.
19. Wire the Voltage Level control to the IO Module\Voltage_Family node, as shown in Figure 14.
20. Add a case structure around the IO Module\SE_Data_Dir, IO Module\SE_Data_Rd, and
IO Module\SE_Data_Wr nodes driven by IO Module\Set_Voltage_Done to prevent input
and output access while the voltage is changing.
Your block diagram should now resemble the block diagram in Figure 14.
21. Save the VI as
22. Close the VI.
23. In the Project Explorer window under My Computer, expand the tree view for your device,
right-click the Static RW with Voltage (FPGA).vi and select Compile to compile the files for
your target.
The Generating Intermediate Files window opens and displays the compilation progress.
The LabVIEW FPGA Compile Server window opens and runs. The compilation takes several
minutes.
24. When the compilation finishes, click the Stop Server button.
25. Click OK in the Successful Compile Report window. Close the VI without saving changes.
NI 6583R User Guide and Specifications
Figure 14. Static RW with Voltage (FPGA).vi Block Diagram
Static RW with Voltage (FPGA).vi
.
20
ni.com

Advertisement