Service Manual
11.2 Removal Procedure of Outdoor Unit
09K
Step
1. Before disassembly
2. Remove big handle and valve cover
Remove the screws fixing big handle, valve cover and
then remove them.
3. Remove top cover
Remove the screws fixing top panel and then remove
the top panel.
Installation and Maintenance
Caution: discharge the refrigerant
completely before removal.
Procedure
Big handle
Valve cover
Top cover
113