Removal Procedure; Removal Procedure Of Indoor Unit - Gree GWH09YCXB-K6DNA1C Service Manual

Table of Contents

Advertisement

11. Removal Procedure

Service Manual

11.1 Removal Procedure of Indoor Unit

NOTE: Take YC model for example.
Step
1. Remove filter
Open the panel. Loosen the clasp shown and then
pull the left filter and right filer outwards to remove
them.
2. Remove horizontal louver
Push out the axile bush on horizontal louver. Bend
the horizontal louver with hand and then separate
the horizontal louver from the crankshaft of step
motor to remove it.
Installation and Maintenance
Procedure
Panel
left filter and right filer
Caution: discharge the refrigerant
completely before removal.
Horizontal louver
Axile bush
109