NIC2-2 · Network ID Camera

7.2 Serial Analyser

See the Network Installation Manual for information.

7.3 System logger

The system logger is a 64 record database where the firmware can report errors and abnor-
mal situations which are not reported to the operator or which may be useful for technicians
to check afterwards. The logger is never erased unless the "Erase" button is pressed. To-
gether with the message, date- and timestamp is stored.
The format of a record is "No:Date Time Error".
No
Index between 00 - 63.
Date Date when the error occurred.
Time Time when the error occurred.
Error The error message in plain text.
ex. "00:100499 08:45 Failed to open lid. Pos = 20".
The errors are divided into four groups; Miscellaneous-, Communication-, Mechanical and
Critical errors. The first three can be set to Record/Ignored. The last one is always active
because it handle internal critical errors such as flash memory reset and checksum error in
set-up memory.
System logger
Setup
Press shift-key to enable the following functions.
Erase
The soft-keys are used as follow.
Setup
Enter the system logger set-up. Possible settings are enable/disable of recording
of Miscellaneous-, Communication- and Mechanical errors. If, for example, a com-
munication problem which occur rarely shall be traced it can be a good idea to
switch the other records of to avoid that the communication records gets overwrit-
ten if the database gets full. This because of the limited number of records in the
list. NOTE! Recording of critical errors can not be switch of.
Up
Scroll the window up.
Down
Scroll the window down.
Exit
Exit the system logger.
Erase
Clear all error messages listed in the system logger. NOTE! If the list is erased, the
data can not be re-created.
Left
Scroll the window to the left.
Right
Scroll the window to the right.
All eventView all records. This can be used if the database is partly corrupt and you want to
view all records even the records which the camera consider being after end mark.