4. Disassembly/Assembly

The camera is opened by removing two big screws, one on each side, and then flip the case
open by pulling the front of the white case upwards.
To get a better view of the opening mechanism and the exposure unit the upper baffle can
be removed by loosening (not removing) the two screws (A) at the front and then pull up-
wards at the front of the baffle.

4.1 The opening mechanism

4.1.1 Disassembly

• Remove the two cables at the back of the exposure unit.
• Check the position of the exposure unit. It can be sledded sidewise and it will be easier
to put it back if we know where it was before. Put a piece of tape on the bottom plate or
measure the distance between the left edge of the bottom plate and the exposure unit.
• Remove the two screws that holds the exposure unit to the bottom plate of the camera.
• Remove the exposure unit by pulling the back of it upwards/slightly backwards and let it
fold until the front is released from the holder.
• Check the position of the optical switch board. It can be sledded sidewise and it will be
easier to put it back if is known where it was before. Unscrew and remove the optical
switch board circuit (A) board to the left of the motor assembly. Let it hang loose in its
cables.