Tador MOON9-KIT User Manual page 10

2-wire video outdoor station
Table of Contents

Advertisement

How to
Return panel settings to factory
mode
Change Programing code
Add an additional opening code
One time code
Delete all of the available codes
Normally open mode
Normally close mode
Open relay timing
If more than one panel is connected in a system you will need to program each of the panel
Set panel 1
Set panel 2
Set panel 3
Set panel 4
What to type
1234*00*1234*
123*01*1234*
1234*20*(code)*
1234*18*(code)*
1234*06*1234*
1234*04*0*
1234*04*1*
*1234*03*05*
to have a different address
*1234*12*0*
*1234*12*1*
*1234*12*2*
*1234*12*3*
-10-
Additional information
Unit will return to the factory
settings
this will change the default
programming code ( 1234* )
In case changing the code
please keep it in a safe place
This will program the code to cell
number 20.
There are 40 cells available to
store access codes.
This will program an one time
access code to the system
This will delete all of the codes
that are stored in the unit
memory
The lock will be used as
normally open usually used for
electric lock
The lock will be used as
normally open usually used for
Magnetic lock
In this setting you will define 5
seconds for the door to be
opened , it is possible to choose
between :
1 – 99 seconds
default : 05 = 5 seconds
This will set address number 1
to the panel which it was
programmed
This will set address number 2
to the panel which it was
programmed
This will set address number 3
to the panel which it was
programmed
This will set address number 4
to the panel which it was
programmed