3. INITIAL SETTINGS
3.5

Heave Sensor Settings

[Heaving Sensor Setting] window allows you to adjust settings related to heaving com-
pensation.
Note 1: Satellite Compass™ connection is required to use the heaving correction
function. If no hull motion information is input from the Satellite Compass™, the heave
sensor compensation function cannot be used.
Note 2: If the [External KP] setting is set to [On] in the [Transducer] menu, the heave
sensor compensation function cannot be used (FCV-800 only).
Note 3: Use of NMEA data converter (NMEA0183 to NMEA2000) is not recommend-
ed.
Note 4: Make sure to set the position of the Satellite Compass™ and transducer. Fail-
ure will result in inefficient performance.
Note 5: To use the heave sensor compensation function, set the output data of the
Satellite Compass™ as follows. For details, refer to the desired Operator's manual.
Output sentence
Baudrate
Output cycle
Version
PGN
1. Press the MENU/ESC key to show the main menu.
2. Select [Calib] and press the KNOB.
3. Select [Heave Sensor Setting] and press the KNOB.
4. Select [Heave Calib] and press the KNOB.
5. To use the heaving compensation function, select [On] and press the KNOB.
When set to [On], the shape of the seabed will be displayed stably even in rough
sea conditions.
NMEA0183
ATT (GPatt), HVE (GPhve)
38,400bps
Lower than 25ms
IEC ED1 (SC-50/110 only)
-
Example of FCV-800 display
41
NMEA2000
-
-
-
-
Heave: 65280
Attitude: 127257