B-4
13. WELD MODE SELECTOR SWITCH:
(Provides 3 selectable welding modes)
CV-WIRE
CC-STICK
TOUCH START TIG
14. ARC CONTROL:
The ARC CONTROL WIRE/STICK knob is active
in the WIRE and STICK modes, and has different
functions in these modes. This control is not
active in the TIG mode.
CC-STICK mode: In this mode, the ARC CON-
TROL knob sets the short circuit current (arc-
force) during stick welding. Increasing the num-
ber from -10(Soft) to +10(Crisp) increases the
short circuit current and prevents sticking of the
electrode to the plate while welding. This can
also increase spatter. It is recommended that the
ARC CONTROL be set to the minimum number
without electrode sticking. Start with a setting at
0.
CV-WIRE mode: In this mode, turning the ARC
CONTROL knob from -10(soft) to +10(crisp)
changes the arc from soft and washed-in to crisp
and narrow. It acts as an inductance/pinch con-
trol. The proper setting depends on the proce-
dure and operator preference. Start with a setting
of 0.
15. WELDING TERMINALS SWITCH:
In the WELD TERMINALS ON position, the out-
put is electrically hot all the time. In the
REMOTELY CONTROLLED position, the output
is controlled by a wire feeder or amptrol device,
and is electrically off until a remote switch is
depressed.
WARNING
• There is no VRD protection in the CV Mode.
• When the Toggle switch is in the "WELD
TERMINAL ON" position the voltage at the
output terminal maybe up to 60V.
-----------------------------------------------------------------------
16. WIRE FEEDER VOLTMETER SWITCH:
Matches the polarity of the wire feeder volt-
meter to the polarity of the electrode.
OPERATION
17. 6 - PIN CONNECTOR:
For attaching optional remote control equipment.
When in the CC-STICK and CV-WIRE modes
and when a remote control is connected to the
Connector, the auto-sensing circuit automatically
switches the OUTPUT control from control at the
welder to remote control.
18. 14-PIN CONNECTOR:
For attaching wire feeder control cable. Includes
contactor closure circuit, auto-sensing remote
control circuit, and 42VAC or 115VAC power.
The remote control circuit operates the same as
the 6-Pin Connector.
19. 42V / 115V WIRE FEEDER VOLTAGE
SWITCH:
Toggles output of 14-pin connector to voltage
requirement of Wire Feeder. (Located above 14-
pin connector.)
20. WELD OUTPUT TERMINALS + AND -
These 1/2" - 13 studs with flange nuts provide
welding connection points for the electrode and
work cables. For positive polarity welding the
electrode cable connects to the "+" terminal and
the work cable connects to this "-" terminal. For
negative polarity welding the work cable con-
nects to the "+" terminal and the electrode cable
connects to this "-" terminal.

AUXILIARY POWER CONTROLS

(Items 21-24)
21. CIRCUIT BREAKERS
These circuit breakers provide separate overload
current protection for each 240V receptacles, the
42VAC and 115VAC in the 14-Pin connector and
battery circuit overload protection.
22. 240 VAC RECEPTACLES
These two 240VAC receptacles provide up to 15
amp total rating each and are IP66 rated. Refer
to the AUXILIARY POWER RECEPTACLES
section in the installation chapter for further infor-
mation about these receptacles. Also refer to the
AUXILIARY POWER OPERATION section later
in this chapter.
AIR VANTAGE® 500 (AU)
B-4