Honeywell SEC-H-602 Manual

Security controller

Advertisement

Quick Links

SEC-H-602 and SEC-H-616
Security Controller
This document covers the mounting and wiring of the WEBs-AX
Controller. It assumes that you are an engineer, technician, or service
person who is performing access system design or installation. Instructions
apply to the following models:
Models
Description
SEC-H-602
Security Controller base unit controller licensed for two
(2) readers, referred to in this document as a "Security
Controller."
SEC-H-616
Security Controller base unit controller licensed for 16
readers, referred to in this document as a "Security
Controller."
NOTE: License expansion reader packs are available in eight (8) reader packs: part number SEC-8-RDR. Sep-
arate documents cover the mounting and wiring of expansion modules.

Table of Contents

Onboard Security I/O ........................................... 2
Expansion Modules .............................................. 2
Option Cards ........................................................ 3
WEBs-AX Security Enclosure .............................. 4
Related Documentation ........................................ 5
Basic Design Rules .............................................. 5
Voltage Drop Considerations ................................ 7
Included in this Package ...................................... 8
Material and Tools Required ................................ 8
Safety Precautions ............................................... 8
Static Discharge Precautions ............................... 8
Environmental Requirements ............................... 9
Physical Mounting ................................................ 9
Removing and Replacing the Cover ..................... 10
About Screw Terminal Connectors ....................... 11
General Wiring Rules ........................................... 12
Connection Overview ........................................... 13
Grounding ............................................................ 13
Cable Types and Lengths ..................................... 13
SECURITY
3TBZ
See "Certifications," page 32.
3TBZ
INSTALLATION INSTRUCTIONS
®
Security
2
Door Terminal Associations .................................. 14
Reader Input ......................................................... 15
Supervised Input .................................................. 16
Relay Output ......................................................... 18
Digital Input .......................................................... 20
5
Ethernet ................................................................ 21
Serial .................................................................... 22
Enclosure Power Supply ....................................... 23
8
Connect the Backup Batteries .............................. 23
Apply Power ......................................................... 24
8
Check the Status LEDs ........................................ 24
About the Backup Batteries .................................. 24
APPENDIXES
9
Using Status LEDs ............................................... 27
Maintaining the Security Controller ...................... 28
Replacement Parts ............................................... 29
Returning a Defective Unit .................................... 31
10
Certifications ......................................................... 32
12
14
21
23
23
31-00012-03

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell SEC-H-602

  • Page 1: Table Of Contents

    SEC-H-602 and SEC-H-616 Security Controller INSTALLATION INSTRUCTIONS ® This document covers the mounting and wiring of the WEBs-AX Security Controller. It assumes that you are an engineer, technician, or service person who is performing access system design or installation. Instructions...
  • Page 2: Product Description Onboard Security I/O

    (SEC-H-R2R/U) mod- ule, if both readers inputs on the Security Controller are utilized. License expansion packs are in 8-reader packs: part SEC-8-RDR. Table 1. Security Controller (SEC-H-602 and SEC-H-616) type expansion modules. Model Description Notes...
  • Page 3: Option Cards

    SEC-H-602 AND SEC-H-616 SECURITY CONTROLLER The Security Controller and its expansion modules all have end-mounted, 6-pin, connectors that support direct If a remote expansion module is mounted in a Security chaining of modules into assemblies. Connectors pass Enclosure without an integral power supply (SEC-ENC-...
  • Page 4: Webs-Ax Security Enclosure

    SEC-H-602 AND SEC-H-616 SECURITY CONTROLLER WEBs-AX Security Enclosure rail (or rails), and include a door with a key lock and tamper switch. Two models have an integral 30W 15Vdc The Security Controller and all expansion modules must power supply that powers the security controller and/or be mounted in one or more WEBs-AX Security the expansion modules inside the enclosure.
  • Page 5: Related Documentation

    4 hours is the intended goal. To achieve (7) 2 reader modules; or if a SEC-H-602 model this, size the Backup Battery(ies) accordingly, using using both the reader inputs, plus any 2 reader the section Estimating Power and Battery Require- modules.
  • Page 6: Estimating Power And Battery Requirements

    Door strikes and other loads should be usage specifications of the readers that you always be powered by other sources. will be using. Table 2. Amps/Watts, Recommended Minimum 12V SLA battery A-Hr capacities, for SEC-H-602 and modules. 12V Backup Battery (4 hours) Max per Amps / W used min.
  • Page 7: Voltage Drop Considerations

    SEC-H-602 AND SEC-H-616 SECURITY CONTROLLER Power Estimate Examples Assuming that all equipment is located relatively nearby, it could be housed in two large enclosures. The security Two example estimates are provided here, as follows: controller is powered by its integral power supply. The second enclosure is powered by a battery-backed 3rd •...
  • Page 8: Maximum Output Load Considerations

    Included in this package you should find the following items: The circuit powering the controller is from 120 to 240Vac at 50/60 Hz. Disconnect power • A Security Controller base controller (SEC-H-602 or before installation or servicing to prevent SEC-H-616). electrical shock or equipment damage.
  • Page 9: Mounting

    SEC-H-602 AND SEC-H-616 SECURITY CONTROLLER Physical Mounting CAUTION The following information applies about physically Work in a static-free area. mounting the unit. Discharge any static electricity you may have • Before mounting the Security Controller, install Option accumulated. Discharge static electricity by Cards, (if any) in the unit.
  • Page 10: Removing And Replacing The Cover

    SEC-H-602 AND SEC-H-616 SECURITY CONTROLLER MOUNTING ON DIN RAIL REMOVING FROM DIN RAIL SEC-ENC-H-2/U ENCLOSURE INCLUDES WIRING HARNESS FOR EXPANSION MODULES. SEC-ENC-H-1/U SEC-ENC-H-2/U SECURITY ENCLOSURE CONTROLLER POWER SUPPLY INSTALL SUPPLIED PHILLIPS HEAD SCREWS IN TAB HOLES MOUNTING TABS ALIGN WITH (2) AND TIGHTEN.
  • Page 11: About Screw Terminal Connectors

    LAN1 COM1 (ONE 4-POSITION CONNECTOR) M35014 Fig. 4. Security Controller (SEC-H-602 or SEC-H-616) board layout details. About Screw Terminal Connectors • Once installed, removal of larger connectors (readers, relay outputs) may be difficult, especially if wiring has Screw-terminal connectors are shipped loose in a been landed.
  • Page 12: Wiring Details

    SEC-H-602 AND SEC-H-616 SECURITY CONTROLLER WIRING DETAILS • Use individually shielded pairs of cable only. All wiring must comply with local, state, and federal electrical codes and fire codes. The following sections provide general wiring information: • General Wiring Rules CAUTION •...
  • Page 13: Connection Overview

    SEC-H-602 AND SEC-H-616 SECURITY CONTROLLER Connection Overview 4. Connect communications cables. See “Communi- cations Wiring,” page 21, for ports available on the See Fig. 4 on page 11 to locate connectors and other Security Controller base unit. components on the Security Controller.
  • Page 14: Security I/O Wiring

    SEC-H-602 AND SEC-H-616 SECURITY CONTROLLER SECURITY I/O WIRING Door Terminal Associations The security controller provides access control for two Security I/O wiring is covered in the following subsections: doors. For each door, the controller allocates: • “Door Terminal Associations,” page 14 •...
  • Page 15: Reader Input

    SEC-H-602 AND SEC-H-616 SECURITY CONTROLLER Reader Input Other Terminal Associations In addition to the pre-allocated I/O for Door Terminal The security controller has two door reader inputs, each Associations, the Security Controller has the following supporting a Wiegand-type 12Vdc reader. Each reader...
  • Page 16: Supervised Input

    SEC-H-602 AND SEC-H-616 SECURITY CONTROLLER Supervised Input NOTE: Supervised inputs SI1 through SI4 are reserved for Door 1 and 2 usage. Supervised The security controller has six (6) supervised inputs, inputs SI5 and SI6 are available for general located on three 3-position connectors next to the DB-9 usage.
  • Page 17 SEC-H-602 AND SEC-H-616 SECURITY CONTROLLER Supervised Input Wiring Notes • At the Security Controller, ground shield drain wires at the enclosure. See Fig. 5 on page 12. • The device monitored by a supervised input should • Connect the two conductors from the device’s contacts...
  • Page 18: Relay Output

    SEC-H-602 AND SEC-H-616 SECURITY CONTROLLER Relay Output Output Status LEDs An LED status indicator for each relay output is located The security controller has four (4) Form-C relay outputs, next to that output’s C (common) terminal on the circuit each rated to switch 24VAC/DC loads up to 3A. Output board—when lit, that relay is energized.
  • Page 19 SEC-H-602 AND SEC-H-616 SECURITY CONTROLLER Auxiliary Relay Output Wiring Figure 11 shows example wiring for controlling an output device. Relay outputs 3 and 4 are available for controlling an auxiliary device, such as a horn annunciator. OUTPUT – DEVICE DEVICE...
  • Page 20: Digital Input

    SEC-H-602 AND SEC-H-616 SECURITY CONTROLLER Digital Input Each digital input can monitor dry contacts, either normally-open (N.O.) or normally-closed (N.C.). All three The security controller has three (3) digital inputs, located inputs are unsupervised—no end-of-line resistors are on a 4-position connector next to supervised input required.
  • Page 21: Communications Wiring

    END PLUG CONNECTOR LUG INPUTS BATTERY M35025 Fig. 13. Security Controller (SEC-H-602 or SEC-H-616) bottom side, cover removed. Ethernet NOTE: Typically, you only use LAN1 (primary port). Do not use LAN2 as the primary port. Two, female 10/100-Mbit Ethernet connections are The default “factory-shipped”...
  • Page 22: Serial

    SEC-H-602 AND SEC-H-616 SECURITY CONTROLLER Serial RS-232 An RS-232 serial port using a male DB-9 connector There are two serial ports on the security controller base always operates as COM1. You can use standard DB-9 unit. At the bottom of the board (see Fig. 13.), the DB-9 is serial cables with this port.
  • Page 23: Power Wiring

    SEC-H-602 AND SEC-H-616 SECURITY CONTROLLER SECURITY 15VDC FROM CONTROLLER WEBS-AX SECURITY SHIELDED, TWISTED ENCLOSURE PAIR CABLING CONNECT RS-485 SHIELD WIRE TO GROUND AT ONE END ONLY. – SEC- SEC-H-RIO/U H-R2R/U SEC- SEC- SEC-H-RIO/U H-R2R/U H-R2R/U NOT SHOWN IS 15VDC POWER AND BATTERY BACKUP CONNECTIONS, WHICH USE THE OTHER (TOP) 3 POSITIONS ON THE 6-POSITION CONNECTOR PLUGS.
  • Page 24: Apply Power

    SEC-H-602 AND SEC-H-616 SECURITY CONTROLLER This connector is keyed—you cannot insert it incorrectly. The red (positive) connection should be the furthest from the two 30-pin option board connectors. Replace the Security Controller cover after connecting the battery. NiMH BATTERY Connect the Backup Battery...
  • Page 25 National Electrical Code. page 24. This battery allows the Security Controller to 4. Digital input DI1 of the SEC-H-602 must be wired to continue station operation (only) through very short power the door tamper switch of its enclosure. See Fig. 12 bumps, meaning a few seconds in duration.
  • Page 26 SEC-H-602 AND SEC-H-616 SECURITY CONTROLLER Compatible Readers Battery-backed Power Supplies Compatible Readers when used with the The following third-party, battery-backed power supplies NPB+PWR+UN+H/U power supply are are UL approved for powering remote SEC-H-R2R/U and SEC-H-RIO/U expansion modules: • HID — Models 5355, 5365, 5375, 5395, 5455, 6005,...
  • Page 27: Using Status Leds

    SEC-H-602 AND SEC-H-616 SECURITY CONTROLLER USING STATUS LEDS The Security Controller includes several LEDs that can help determine the status of the unit. They are located in two places: the top of the controller (visible through the cover), and for relay outputs and serial ports, on the bottom board (visible with cover removed).
  • Page 28: Maintaining The Security Controller

    SEC-H-602 AND SEC-H-616 SECURITY CONTROLLER Serial Port LEDs The NiMH battery in the Security Controller is fully discharged when factory shipped. Additionally, NiMH LEDs for the two serial ports are located on the Security batteries lose charge over time if not kept trickle-charged Controller’s bottom board, near the DB-9 connector (see...
  • Page 29: Replacement Parts

    SEC-H-602 AND SEC-H-616 SECURITY CONTROLLER REPLACEMENT PARTS Fuse The Security Controller contains a non-user replaceable Servicing the Security Controller may call for replacement fuse, soldered on the circuit board. This fuse provides parts. There are three categories of parts: protection from internal shorts or connection to incorrect power supplies.
  • Page 30: Replacing The Security Controller Base Assembly

    SEC-H-602 AND SEC-H-616 SECURITY CONTROLLER REPLACING THE SECURITY and pull out from the circuit board. See “About Screw Terminal Connectors,” page CONTROLLER BASE ASSEMBLY 7. Unplug the 6-position end-connector plug from the Security Controller, if present. 8. Remove the screws in the two mounting tabs, and...
  • Page 31: Returning A Defective Unit

    SEC-H-602 AND SEC-H-616 SECURITY CONTROLLER RETURNING A DEFECTIVE For proper credit on an in-warranty unit, ship the defective unit to Tridium within 30 days. UNIT Prior to returning the unit, contact one of the following Tridium offices to obtain a return authorization (RA) NOTE: If the defective unit is under warranty, please number and other instructions.
  • Page 32: Certifications

    By using this Honeywell literature, you agree that Honeywell will have no liability for any damages arising out of your use or modification to, the literature. You will defend and indemnify Honeywell, its affiliates and subsidiaries, from and against any liability, cost, or damages, including attorneys’...

This manual is also suitable for:

Sec-h-616

Table of Contents