Indoor Air Quality System Settings Tables; Air Cleaning Sytem Settings Table; Humidifier System Settings Table; Dehumidifier System Settings Table - Aprilaire 8910 Safety & Installation Instructions

Touch screen thermostat with integrated indoor air quality solutions
Hide thumbs Also See for 8910:
Table of Contents

Advertisement

SETUP & TESTING

INDOOR AIR QUALITY SYSTEM SETTINGS TABLES

The following tables contain the Indoor Air Quality system settings and their details . Default settings are shown in
bold . Some settings are only present dependent upon the value of other settings .
The use of an outdoor temperature sensor (recommended) enables additional Indoor Air Quality functionality . If the
outdoor temperature sensor was not enabled in the HVAC system settings, HVAC system setting 11, outdoor sensor,
will be presented prior to entering the Indoor Air Quality system settings .
Please refer to the Model 8910 Owner's Manual for further information about thermostat features .
Air Cleaning System Settings Table
System setting
Description
Air Cleaner Installed
Selects if an air cleaner is installed . (If set to no, no other
air cleaning settings will be available .)
Change Air Filter Reminder
The period for displaying the "Change Air Filter" message .

Humidifier System Settings Table

System setting
Description
Selects if a humidifier is installed . Yes/On HVAC is used
Humidifier Installed
for applications where the humidifier is installed on the
HVAC duct . Yes/Standalone is used for application where
the humidifier is independent of the HVAC system . (If set to
no, no other humidifier settings will be available .)
Humidifier Mode
Selects auto or manual mode . Auto mode controls humidity
based on the humidity setting and outdoor temperature .
Manual mode controls humidity based on the %RH setpoint .
(Auto mode is only available if outdoor sensor is set to
Installed .)
Humidity Setpoint
Selects the minimum difference between the humidifier
Deadband
and dehumidifier setpoints . (Only available if a humidifier is
installed and dehumidifier control is set to air conditioner .
Available in both set-ups .)
Humidifier Operation
Selects when humidification is allowed to occur relative
to heating and fan operation . Without Fan allows
humidification to occur without the HVAC fan . This option
should only be used when the humidifier is independent
of the HVAC system . Note: Without Fan is only available
when Humidifier Installed is set to Yes/Standalone .
CAUTION: When Humidifier Operation is set to Without Fan the thermostat will turn on humidification
without energizing the HVAC fan . Do not select this option when the humidifier is installed on the HVAC duct .
Without airflow moisture can accumulate in the duct resulting in significant damage .
Change Water Panel
Selects the when the "Change Water Panel" message is
Reminder
displayed .
14
Factory default setting (bold)
and setting range
No
Yes
Off
1 to 12 months or "Off" to disable
Factory default setting (bold)
and setting range
No
Yes/On HVAC
Yes/Standalone
Auto
Manual
10 Percent RH
10 to 20 Percent RH
Heat Only
Heat or Fan
Forces Fan
Without Fan
Off
1 Per Season
2 Per Season
300 Hours
600 Hours
SETUP & TESTING
System setting
Description
Reminder Month (Change
Change Water Panel Reminder set to 1 per Season:
Water Panel Reminder set
Determines the month the "Change Water Panel" message
to 1 per Season)
is displayed .
First Reminder Month
Change Water Panel Reminder set to 2 per Season:
(Change Water Panel
Determines the first month the "Change Water Panel"
Reminder set to 2 per
message is displayed .
Season)
Second Reminder Start
Determines the second month the "Change Water Panel"
Month
message is displayed . (Only available when Change Water
Panel Reminder set to 2 per Season .)

Dehumidifier System Settings Table

System setting
Description
Dehumidifier Control
Selects method of dehumidification .(If set to none, no
other dehumidifier settings will be available .)
Humidity Setpoint Deadband
Select the minimum difference between the humidifier
and dehumidifier setpoints . (Only available if both a
humidifier and dehumidifier are installed . Available in
both set-ups .)
Lockout Dehumidifier During
Selects if dehumidification is disabled during a cooling
Cooling
call .
Dehumidifier Forces Fan
Select if dehumidification can turn on the fan .
Dehumidifier Service
The period for displaying the "Dehum Service
Reminder
Reminder" message .
Dehumidifier Overcooling
Selects the amount of overcooling that can occur for
Limit
dehumidification . (Only available if dehum control is
set to air conditioner .)
Dehumidify in Vacation
Selects if dehumidification with the air conditioner
Mode
is done in Vacation Mode . (Only available if dehum
control is set to air conditioner .
Vacation Dehumidifier Low
Sets the lowest temperature the air conditioner will
Temp Limit
cool to meet RH setpoint in Vacation Mode . (Only
available if dehum control is set to air conditioner .)
Note: Refer to manuals for humidifier, dehumidifier, air cleaner and ventilation products for recommended
installation and operation .
Factory default setting (bold)
and setting range
October
November
December
January
February
March
April
May
June
July
August
September
October
November
December
January
February
March
April
May
June
July
August
September
Factory default setting (bold)
and setting range
None (no dehumidification installed)
Whole Home
Air Conditioner
10 Percent RH
10 to 20 Percent RH
No
Yes
No
Yes
Off
1 to 12 months or "Off" to disable
3°F (1.5°C)
1°F to 3°F (0 .5°C to 1 .5°C)
No
Yes
75°F (24°C)
70°F to 85°F (21°C to 29°C)
15