5.6

Boiler fixing

 Fix the bolt 6) and nut 7) onto the flange 1) as in Fig. 6.
 Fix the flange 1) to the appliance 4) using the supplied bolts
2) and nuts 3) with the gasket 5) in-between as in Fig. 7.
 Insert the burner tube through the flange and push to ensure
full insertion. With the burner collar fully inserted into the
flange the O-ring will form a seal.
 Fix the securing nut 8)(Fig. 6) onto the bolt 6).
The seal between burner and boiler must be
airtight.
WARNING
5.7

Burner assembly

The temperature of the incoming air must not
exceed 70 °C.
CAUTION
For correct BF application, the burner must be in-
stalled on an appropriate BF boiler.
WARNING
In case of BF applications an optional snorkel and gasket are
available.
This item can be supplied separately.
2903310
5
1
E9094
Installation
8
7
2
12
GB
E9095
3
4
D5883
6
1
Fig. 6
Fig. 7
B
Fig. 8