Download Print this page

Harman Kardon AVR145/230 Service Manual page 3

5 x 40w 5.1 channel a/v receiver

Advertisement

harman/kardon
SAFETY PRECAUTIONS
The following check should be performed for the continued
protection of the customer and service technician.
LEAKAGE CURRENT CHECK
Measure leakage current to a known earth ground (water
pipe, conduit, etc.) by connecting a leakage current tester
between the earth ground and all exposed metal parts of the
appliance (input/output terminals, screwheads, metal
overlays, control shaft, etc.). Plug the AC line cord of the
appliance directly into a 120V AC 60Hz outlet and turn the
AC power switch on. Any current measured must not exceed
o.5mA.
Device
under
test
Also test with
plug reversed
(Using AC adapter
plug as required)
ANY MEASUREMENTS NOT WITHIN THE LIMITS
OUTLINED ABOVE ARE INDICATIVE OF A
POTENTIAL SHOCK HAZARD AND MUST BE
CORRECTED BEFORE RETURNING THE APPLIANCE
TO THE CUSTOMER.
Reading should
not be above
Leakage
0.5mA
current
tester
Test all
exposed metal
surfaces
AC Leakage Test
Earth
ground
AVR 145/230 service manual
Page 3 of 135

Advertisement

loading

This manual is also suitable for:

Avr145