Figure 9: Connecting the RUGGEDCOM WIN1010 PoE Injector
1. Subscriber Station    2. PoE Cable    3. Switch or Router    4. Ethernet    5. RUGGEDCOM WIN1010    6. AC Power Cable    7. AC Power
4.
Connect a CAT-5e cable between the RUGGEDCOM WIN1010 and a 10/100Base-T port of a switch or router.
5.
Make sure all system components are properly installed and all cable connectors are securely positioned in
the appropriate ports.
6.
Connect the data adapter to the 110/220 VAC mains.
Section 2.9.3

Connecting to a RUGGEDCOM RP100 or RP110 (AC Only)

The RUGGEDCOM RP100 and RP110 are optional power injectors for powering and providing data to the
RUGGEDCOM WIN5137 (AC Only). The RUGGEDCOM RP100 and RP110 meet a wider temperature and voltage
range than the standardRUGGEDCOM WIN1010.
When the subscriber station is connected to a RUGGEDCOM RP100 or RP110, make sure there is a solid connection
between the lightning protector and the subscriber station. The following illustration details a typical installation.
NOTE
A shielded cable must be used and connected to local ground at both the subscriber station and
lightning protector.
NOTE
The lightning protector must meet the necessary requirements of IEC/UL/CSA 60950-1. The clamping
voltage must also be less than 60 V and the protector must not activate when the voltage is less than
56 V. For more information about these requirements, contact Siemens Customer Support.
IMPORTANT!
Install the lightning protector and the RUGGEDCOM RP100/RP110 as close as possible.
18
2
1
3
4
4
5
6
7
Connecting to a RUGGEDCOM RP100 or RP110 (AC Only)
RUGGEDCOM WIN5137
Installation Guide