Connecting Power

The RUGGEDCOM RS8000H supports a single integrated high AC/DC or low DC power
supply
2.4.1

Connecting AC Power

To connect a high AC power supply to the device, do the following:
Electrical hazard – risk of damage to equipment
Before testing the dielectric strength (HIPOT) in the field, remove the braided
ground cable connected to the surge ground terminal and chassis ground. This cable
RUGGEDCOM RS8000H
Installation Manual, 11/2022, C79000-G8976-1022-07
1
2
3
Normally Closed
Common
Normally Open
Failsafe Alarm Relay Wiring
NOTICE
For 88-300 VDC rated equipment, an appropriately rated circuit breaker must be
installed.
For 100-240 VAC rated equipment, an appropriately rated circuit breaker must
be installed.
Use minimum #16 gage wiring when connecting terminal blocks.
A circuit breaker is not required for 12, 24 or 48 VDC rated equipment.
Power input terminals have reverse polarity protection for 12, 24 and 48 VDC
rated equipment.
Equipment must be installed according to applicable local wiring codes and
standards.