Installing The Antennas - Siemens RUGGEDCOM WIN5137 Installation Manual

Hide thumbs Also See for RUGGEDCOM WIN5137:
Table of Contents

Advertisement

RUGGEDCOM WIN5137
Installation Guide
Figure 6: Mounting the Subscriber Station to a Small Pole
1. Subscriber Station    2. Pole    3. Clamping Bracket    4. Mounting Bracket    5. M8-25 Hex Screw    6. M8 Spring Washer    7. M8 Flat
Washer    8. M8 Nut    9. M8-70 Hex Screw
2.
Liberally apply an anti-corrosion spray to all galvanized steel components, including mounting brackets, nuts,
washers and screws.
3.
Select a mounting location on the pole.
4.
Position the mounting bracket against the pole.
NOTE
When mounting the subscriber station, note the orientation of the clamping bracket in
Figure
5.
Secure the clamping bracket to the mounting bracket using screws, spring washers and nuts. Make sure the
screws are hand tightened.
6.
Make sure the subscriber station is properly grounded according to local standards. For more information,
refer to
Section 2.8, "Grounding the Subscriber
7.
Tighten the screws connecting the clamping bracket to the mounting bracket. Make sure the screws are
torqued to 14 N·m (10 lbf-ft).
Section 2.7

Installing the Antennas

The RUGGEDCOM WIN5137 supports N-Connect female antennas.
To install an antenna, do the following:
WARNING!
Radiation hazard – risk of Radio Frequency (RF) exposure. This subscriber station is compliant with
the requirements set forth in FCC CFR 47, section 1.1307, addressing Radio Frequency (RF) exposure
Installing the Antennas
4
3
5
6
7
6.
6
8
Station".
Installing the Subscriber Station
2
7
7
6
9
Figure 5
Chapter 2
1
3
or
13