E5CSL/E5CWL/E5EWL

Ordering Information

E5CSL
Size
Power supply voltage
1/16 DIN
48 48 60
100 to 240 VAC
(W H D)
E5CWL
Size
Power supply voltage
1/16 DIN
48 48 60
100 to 240 VAC
(W H D)
E5EWL
Size
Power supply voltage
1/8 DIN
48 96 60
100 to 240 VAC
(W H D)
Accessories (Order Separately)
Terminal Cover
Model
Front Panel (for E5CSL/E5CWL)
Model
Note: 1. This Front Panel accessory is required to attach the Y92A-
48B or Y92A-48D.
2. This Front Panel accessory is only the frame.
It does not include the plastic cover.
Specifications
Ratings
Power supply voltage
Operating voltage range
Power consumption
Sensor input
Relay output
Control
Voltage output
output
(for driving
SSR)
Alarm output (See note.)
Control method
Setting method
Indication method
Other functions
Ambient operating
temperature
Ambient operating humidity
Storage temperature
Note: E5CWL/E5EWL only
2
Arrow.com.
Arrow.com.
Downloaded from
Downloaded from
Input type
Thermocouple
Resistance thermometer
Thermocouple
Resistance thermometer
Input type
Thermocouple
Resistance thermometer
Thermocouple
Resistance thermometer
Input type
Thermocouple
Resistance thermometer
Thermocouple
Resistance thermometer
E53-COV19
E53-COV20
100 to 240 VAC, 50/60 Hz
85% to 110% of rated supply voltage
3.5 VA
Models with thermocouple inputs
Thermocouple: K, J, T, R, or S
Models with platinum resistance thermometer inputs
Platinum resistance thermometer: Pt100
SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum load: 5 V, 10 mA
Output voltage: 12 VDC 25%/15% (PNP), max. load current: 21 mA, with short-circuit protection circuit
SPST-NO, 250 VAC, 1 A (resistive load), electrical life: 100,000 operations, minimum load: 5 V, 10 mA
ON/OFF control or 2-PID control (with auto-tuning)
Digital setting using front panel keys
7-segment digital display and individual indicators
Character height: E5CSL: 21.7 mm, E5CWL: 16.2 mm (PV), E5EWL: 20 mm (PV)
Temperature input shift, run/stop, protection functions, etc.
10 to 55C (with no icing or condensation)
25% to 85%
25 to 65C (with no icing or condensation)
Alarm output
Control output
Relay output
None
Voltage output
(for driving SSR)
Alarm output
Control output
Relay output
1
Voltage output
(for driving SSR)
Alarm output
Control output
Relay output
1
Voltage output
(for driving SSR)
Adapter
Model
 Use this Adapter when the Front Panel has
already been prepared for the E5B@.
Y92F-45
 Only black is available.
 Order separately.
 Use for E5CSL/E5CWL only.
Y92F-49
 Provided with E5CSL/E5CWL.
 Use for E5EWL only.
Y92F-51
 Provided with E5EWL.
Model
E5CSL-RTC
E5CSL-RP
E5CSL-QTC
E5CSL-QP
New model
E5CWL-R1TC
E5CWL-R1P
E5CWL-Q1TC
E5CWL-Q1P
New model
E5EWL-R1TC
E5EWL-R1P
E5EWL-Q1TC
E5EWL-Q1P
Remarks