general information
EN
1.1
rates and effi ciencies
Appliance Type
Fuel Type
Altitude (FT)
Max. Input (BTU/HR)
Min. Input (BTU/HR)
Appliance Type
Fuel Type
Altitude (FT)
Max. Input (BTU/HR)
Min. Input (BTU/HR)
Appliance Type
Fuel Type
Altitude (FT)
Max. Input (BTU/HR)
Min. Input (BTU/HR)
Min. Inlet Gas Supply
Pressure
Max. Inlet Gas Supply
Pressure
Manifold Pressure (Under
Flow Conditions)
*Maximum inlet pressure not to exceed 13" w.c. (32mb).
6
W415-4121 / B / 04.20.23
TLV50N
Natural Gas
36,000
TLV62N
Natural Gas
44,000
29,000
TLV74N
Natural Gas
48,000
30,000
TLV50 / TLV62 / TLV74
Natural Gas
4.5" w.c. (11mb)
11" w.c. (27mb)
7"* w.c. (17mb)
13" w.c. (32mb)
3.5" w.c. (9mb)
10" w.c. (25mb)
TLV50
TLV50P
Propane
0-4,500
31,500
25,000
TLV62
TLV62P
Propane
0-4,500
38,000
28,000
TLV74
TLV74P
Propane
0-4,500
41,500
33,000
Propane
4.5" w.c. (11mb)
13" w.c. (32mb)
3.5 w.c. (9mb)
11" w.c. (27mb)
13" w.c. (32mb).
10" w.c. (25mb)