1. Attention

a. The specific instructions below related to the safe operation of the heat pump are set out below in accordance
with AS/NZS60335-1 and AS/NZS60335-2-40.
b. Installation requirements are detailed in the Installation Guidance section of this Manual.
c. The heat pump must be installed by 1. A qualified person, 2. In accordance with the installation instructions and
3. In compliance with Standards AS/NZS 3000, AS/NZS 3500.4 as applicable under local regulations and all
local codes and regulatory authority requirements.
d. In New Zealand, the installation must also conform with NZS 5261, as applicable under local regulations, and
the NZ Building Code.
e. The heat pump is supplied as a package unit, ready for immediate operation after installation with the provision
of power supply and direct connection to your swimming pool via PVC piping as outlined in the hydraulic sections
of this Manual.
f.
It is suitable for outdoor installation only and clearance guidelines are outlined in this Manual.
g. Connection to water mains is not intended.
h. For electrical connection, the selection of type and rating of fuses should be in accordance with the Installation
Guidance Section of this Manual.
i.
The heat pump is a closed refrigeration system using the low GWP Refrigerant R32. As such, compliance with
national gas regulations shall be observed.
j.
Do not pierce or burn.
k. Be aware that refrigerants may not contain an odour.
l.
Do not use means to accelerate the defrosting process or to clean, other than those recommended by the
manufacturer.
m. The heat pump should be located to prevent the risk of mechanical damage from external sources.
n. If a repair is required, please contact the nearest after-sales service center. The repair process must be strictly
in accordance with manual. All repair practice by non-professional is prohibited.
o. Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid
certificate from an industry-accredited assessment authority, which authorises their competence to handle
refrigerants safely in accordance with an industry recognised assessment specification. Servicing shall only
be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the
assistance of other skilled personnel shall be carried out under the supervision of the person competent in the
use of flammable refrigerants.
p. A leakage test must be performed after installation.
q. Please don't stack substances, which will block air flow near inlet or outlet area, otherwise the efficiency of the
heat pump will be reduced or even stopped.