Rheem RPH Series User Manual page 17

Swimming pool heat pump
Table of Contents

Advertisement

f.
Defrost
1) Automatic defrosting: When the unit is in auto defrosting mode this symbol
finished. Once finished it will go back to normal operating mode.
2) Manual Defrost: To enter the forced defrosting mode, the compressor must have been operating for
more than 10 minutes.
In heating mode, press
forced defrost mode and this symbol
flashing the defrosting mode stops and the unit will resume normal operation.
(Note: the intervals between forced defrosting should be more than 30 minutes)
g. Wi-Fi Setting
When the screen is on, press
Wi-Fi connection. Connect the Wi-Fi on your mobile device and input the password, and then control
equipment by Wi-Fi. When the Wi-Fi APP successfully connects the Wi-Fi symbol
on.
h. Running Status Checking
1)
Press
symbol for 5 seconds, the unit will then start to run the checking status
During this time, the display will show the status symbol "C0" and its corresponding value.
2)
3)
Change status by pushing the
to quit the "Running Status Checking" mode.
4)
Press
5)
Running status checking table:
and
on buttons together simultaneously for 5 seconds to start the
is flashing the defrost function starts. Once
for 3 seconds, when this symbol
and
Symbol
C0
Inlet water temp
C1
Outlet water temp
C2
Ambient temp
C3
Exhaust gas temp
C4
Evaporator coil pipe temp
C5
Return gas temp
C6
Cooling coil pipe temp
C9
Cooling plate temp
C10
EEV opening angle
C11
DC fan speed
arrows to the corresponding value.
Content
14
will flash until it is
stops
starts to flash, enter the
light stays
Unit
°C
°C
°C
°C
°C
°C
°C
°C
P
r/min