Pressure Relief Procedure - Graco Magnum Pro Plus A30 Operation Instructions Manual

Hide thumbs Also See for Magnum Pro Plus A30:
Table of Contents

Advertisement

Pressure Relief Procedure

Follow this Pressure Relief Procedure whenever you
stop spraying and before cleaning, checking, servicing,
or transporting equipment.
1. Turn OFF power switch.
ti2018a
2. Place prime tube in waste pail.
ti2034a
3A1177B
3. Turn Prime/Spray valve to PRIME.
ti2019a
4. Turn pressure control knob left (minimum pressure).
ti2020a
5. Trigger gun into bucket to relieve pressure in hose.
ti2033a