Graco Magnum Pro Plus A30 Operation Instructions Manual page 20

Hide thumbs Also See for Magnum Pro Plus A30:
Table of Contents

Advertisement

Troubleshooting
Problem
Pump cycles but pressure does
not build up.
Cannot pull gun trigger.
Gun stops spraying.
Pump cycles but paint only
dribbles or spurts when trigger is
pulled.
Pressure set at maximum, but
cannot achieve good spray
pattern.
20
Cause
Pump not primed.
Inlet screen clogged.
Suction tube not immersed.
Paint pail empty.
Suction tube has vacuum air leak. Tighten suction tube connection. Inspect for cracks or
Pump check valves are dirty or
damaged.
Prime/Spray valve worn or
obstructed with debris.
Pump check ball stuck.
Gun trigger safety engaged.
Spray tip clogged.
Pressure is set too low.
Spray tip clogged.
Spray tip too large or worn.
Gun filter clogged.
Fluid filter is clogged.
Pump check ball stuck.
Tip is too large for sprayer.
Tip is worn beyond capability of
sprayer.
Gun filter clogged.
Inlet screen clogged.
Pump valves worn.
Fluid filter clogged.
Extension cord too long or not
heavy enough gauge.
Solution
Prime pump, page 12.
Clean debris off inlet screen
Reposition suction tube in bottom of paint pail.
Refill paint pail and reprime sprayer.
vacuum leaks. If cracked or damaged, replace.
Return sprayer to Graco/M
AGNUM
center.
See "Pump will not prime" section of Troubleshooting
table. Press pump priming button two times.
Remove gun trigger safety
1
Turn arrow-shaped handle to unclog position.
2
Aim gun into waste pail.
3
Squeeze trigger.
4
Return arrow-shaped handle to spray position and
begin spraying.
Turn pressure control knob right to increase pressure.
Clean tip. See "Gun stops spraying" section of
Troubleshooting table.
Replace tip.
Clean or replace gun filter, page 17.
Clean or replace fluid filter.
See "Pump will not prime" section of Troubleshooting
table.
Select smaller tip, Tip Hole Size, page 13.
Replace tip.
Clean or replace gun filter, page 17.
Clean debris off inlet screen.
Check for worn pump valves:
1
Prime sprayer with paint.
2
Trigger gun momentarily. When trigger is released,
pump should cycle and stop.
3
If pump continues to cycle, pump valves may be
worn.
4
Return sprayer to Graco/M
service center.
Clean or replace fluid filter.
Replace cord, Grounding Information, page 6.
authorized service
authorized
AGNUM
3A1177B

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magnum pro plus a4516e66416e665

Table of Contents