Download Print this page
Cornelius P/N 620037008 Installation Instructions
Cornelius P/N 620037008 Installation Instructions

Cornelius P/N 620037008 Installation Instructions

These bin stat kits apply to all “i” series ice makers

Advertisement

Quick Links

IMI CORNELIUS INC g One Cornelius Place g Anoka, MN 55303-6234
Telephone (800) 238-3600
INSTALLATION INSTRUCTIONS, BIN STAT KIT, P/N 630000408
These Bin Stat kits apply to all "I" Series Ice makers
Item No.
Part No.
1
630900413
2
70894
3
51348
4
630000413
5
620037008
6
630460064INS
7
168833002
1. Disconnect power.
2. Remove front cover of the unit and the electrical box cover plate.
3. Carefully insert the coiled capillary tube through the bottom hole in the electrical box where the elec-
trical wires are coming through (see Figure 4).
4. If there is not a hole already in the chassis base, drill a ½" hole in the chassis base as indicated in
Figure 3.
5. Straighten approximately 12" of cap tube to go through hole. Re–coil the remainder. Do not disturb
coiled end.
6. Insert the "1/4" diameter wire form support into the coiled end of capillary tube and insert the assem-
bly through the hole in the chassis base. Route capillary tube to follow support as closely as pos-
sible.
7. Remove the 8–32 nut (closest to the ½" DIA hole) that holds the compartment wall to the base. The
adapter kits that have a single level, adapter kits P/N's 02390, 630200153, 08006, 02388, 08004,
630000191 and 08010) require a 7/8" high spacer be used to mount the binstat support. Thread the
8–32 x 5/8" hex spacer on to the compartment stud. Then fasten the thermostat support to the hex
spacer using the ¼" high plastic spacer, #8 flat washer and 8–32 x ¾" long phil. head screw. The
spacers are not to be used on the elevated adapter kits. Refer to Figure 2.
8. Any excess capillary tubing must be pulled back into the compressor compartment to prevent ice
from damaging it during dispenser operation.
9. Seal ½" diameter hole with sealant (RTV).
IMI CORNELIUS INC. 2004
Table 1. Loose–Shipped Parts
Name
Spacer, Hex 5/8" Long x 8–32 SS
Screw MA 08–32 TRPH 24 SS
Spacer
Thermostat Asy
Bin Stat Support
Installation Instruction, Thermostat
Washer SR 4W SS E#8
1
Facsimile (800) 535-4321
Qty.
1
1
1
1
1
1
1
March 2, 2004
Rev A
630460064INS

Advertisement

loading

Summary of Contents for Cornelius P/N 620037008

  • Page 1 IMI CORNELIUS INC g One Cornelius Place g Anoka, MN 55303-6234 Telephone (800) 238-3600 INSTALLATION INSTRUCTIONS, BIN STAT KIT, P/N 630000408 These Bin Stat kits apply to all “I” Series Ice makers Table 1. Loose–Shipped Parts Item No. Part No.
  • Page 2 DUE TO UPGRADING OF CIRCUIT BOARD NOTE LOCATION OF SENSORS AND WIRE CONNECTIONS ON NEW BOARD. FOLLOW SETTINGS #1–#4 FOR HARVEST SETTINGS. FOLLOW SETTINGS #5–#7 FOR NUMBER OF CURTAINS. IMI CORNELIUS INC. 2004 External Error LED Connection Cond. Suction line...
  • Page 3 March 2, 2004 IMI CORNELIUS INC. 2004 Rev A 630460064INS...
  • Page 4 ICEMAKER E-BOX CAPILLARY TUBE ELEVATED ADAPTOR KIT SINGLE LEVEL ADAPTOR KIT BIN STAT SUPT ASY FOR SINGLE LEVEL ADAPTOR KIT NO: 02388, 08004,630000191, 02390, 630200153, 08006, & 08010 8–32 X 3/4 PHMS BIN STAT SUPT ASY FOR ALL ELEVATED ADAPTOR LID KITS FIGURE 2 WASHER 620037008, BIN STAT SUPT...
  • Page 5 DROP ZONE DROP ZONE DROP ZONE 15.41 ELECTRICAL BOX ASY THERMOSTAT KIT ASY 630000408 COIL IMI CORNELIUS INC. 2004 DROP ZONE 1/2” DRILL 4.25* 1.50 * DIMENSION IS FROM FRONT OF UNIT WITHOUT COVER. Figure 3 TO CHASSIS PLATE Figure 4...

This manual is also suitable for: