Manifold Connectors - Emerson Aventics G3 Series Technical Manual

Profibus dp-v0 dp-v1
Hide thumbs Also See for Aventics G3 Series:
Table of Contents

Advertisement

2.3

Manifold Connectors

Solenoid Coil Connections using Z-Board™ Technology for 50x valve series
Z-Board™ plug together technology connects all valve solenoids to the valve coil output driver board, located in the
valve adapter. There is a maximum of 32 coil outputs available on the complete manifold assemblies. The 32 available
outputs are accessed on the 501 series valves utilizing 3 and 4 station manifolds and on the 502 and 503 series
utilizing 2 station manifolds.
NOTE!
G3 Series PROFIBUS-DP
A single solenoid valve's coil is always on the "14" end.
TDG3PTTM1-11EN
Subject to change without notice
www.asco.com
Technical Manual
TM
Not Used,
Pin No. 3
Common,
12 Solenoid,
Pin No. 4
Pin No. 2
07/2020
14 Solenoid,
Pin No. 1