Installation Overview
Item
#
1
2
3
4
5
6
7
8
9
Before you begin
Note
The pole or mast must be rigid enough to hold the weight of an access point along with the associated forces
produced by wind loads. In addition, the mast must be structurally strong enough to withstand the clamping
force of the hose clamps.
Procedure
Step 1
Determine the mounting location for the access point on the pole or mast.
Step 2
Position and mount the pole mounting flange onto the pole or mast using the hose clamps provided in the kit.
The hose clamps should pass through the slots on the free mounting flange bracket.
Step 3
Tighten the hose clamps and set screws until the flange is fully secure on the mast.
Adjust the flange to its final position. Then, use a slotted screwdriver to tighten the screws on the hose clamps.
Step 4
Attach the AIR-AP-BRACKET-2 to the access point bracket using four M4 screws through the holes in the
bracket.
Snugly hand tighten the M4 four screws included in the mounting kit.
Step 5
Assemble the mounting arm to connect the pole mounting flange and the access point bracket.
Hand tighten all screws and nuts. See
Hose Clamp Assembly, on page
Step 6
Attach the access point to the AIR-AP-BRACKET-2.
Mounting Bracket Kit
M4 X 10mm screw with washer
AIR-AP-BRACKET-2
Not included in this kit.
Access point bracket plate
M8 x40 Hex bolts
Mounting arm
M8 washer (external-tooth)
M8 flanged lock nut
Pole or wall mounting flange
Hose clamp 2.5" to 5" (63.5 to 127mm)
diameter
24.
Cisco Catalyst Wireless 9166D1 Wi-Fi 6E Access Point Hardware Installation Guide
Mounting on a Pole or Mast Using Articulating Bracket
Quantity
Tightening Values
4
Snug, hand tight
1
1
2
1
2
2
5.6 lb-ft to 5.9 lb-ft (7.6 Nm to 8.0 Nm)
1
2
Figure 22: Exploded View of the Pole Mounting Articulating Bracket