  • Page 1 Meraki CW9166D1-MR Hardware Installation Guide...
  • Page 2 Statement of Conditions In the interest of improving internal design, operational function, and/or reliability, Cisco Systems reserves the right to make changes to the products described in this document without notice. Cisco Systems does not assume any liability that may occur due to the use or application of the product(s) or circuit layout(s) described herein.
  • Page 3: Table Of Contents

    Table of Contents Scope of Document and Related Publications CW9166D1-MR Overview 2.1 Package Contents 2.2 Understanding the CW9166D1-MR 2.3 Security Features 2.4 Ethernet Ports 2.5 Power Source Options 2.6 Factory Reset Button 2.7 LED Indicators and Run Dark Mode Pre-Install Preparation 3.1 Configure Your Network in Dashboard 3.2 Check and Upgrade Firmware 3.3 Check and Configure Firewall Settings...
  • Page 4: Scope Of Document And Related Publications

    Scope of Document and Related Publications The CW9166D1-MR Hardware Installation Guide describes the installation procedure for the CW9166D1-MR indoor access point. Additional reference documents are available online at www.meraki.com/library/product.
  • Page 5: Cw9166D1-Mr Overview

    CW9166D1-MR Overview The Meraki CW9166D1-MR is an enterprise-class, dual-concurrent 4x4 MIMO 802.11ax indoor access point designed for high-density deployments in offices, schools, hospitals and hotels. When connected to the Meraki Cloud Controller, the CW9166D1-MR enables the creation of ultra-high speed, reliable indoor wireless networks quickly, easily and cost- effectively.
  • Page 6: Security Features

    2.3 Security Features The CW9166D1-MR features multiple options for physically securing the access point after installation: 1. Security screw – The accessory kit includes screws that can be used to secure the access point to the mount plate. Engaging the security screw prevents accidental dislodging and theft.
  • Page 7: Pre-Install Preparation

    Pre-Install Preparation You should complete the following steps before going on-site to perform an installation. 3.1 Configure Your Network in Dashboard The following is a brief overview only of the steps required to add an CW9166D1-MR to your network. For detailed instructions about creating, configuring and managing Meraki wireless networks, refer to the Meraki Cloud Controller Manual (meraki.com/library/product).
  • Page 8: Assigning Ip Addresses To Cw9166D1-Mrs

    3.4 Assigning IP Addresses to CW9166D1-MRs All gateway CW9166D1-MRs (CW9166D1-MRs with Ethernet connections to the LAN) must be assigned routable IP addresses. These IP addresses can be dynamically assigned via DHCP or statically assigned. 3.4.1 Dynamic Assignment When using DHCP, the DHCP server should be configured to assign a static IP address for each MAC address belonging to a Meraki AP.
  • Page 9: Collect Tools

    3.5 Collect Tools You will need the following tools to perform an installation: Phillips Hammer Drill with 1/4” screwdrive (6.3mm) bits 3.6 Collect Additional Hardware for Installation 802.3at PoE power source (either AC Adapter PoE switch or Meraki 802.3at PoE Injector) Network cables with RJ45 connectors long enough for your particular mounting...
  • Page 10: Installation Instructions

    Installation Instructions 4.1 Choose Your Mounting Location A good mounting location is important to getting the best performance out of your CW9166D1-MR access point. Keep the following in mind: 1. The device should have unobstructed line of sight to most coverage areas. For example, if installing in an office filled with workspaces divided by mid-height cubicle walls, installing on the ceiling or high on a wall would be ideal.
  • Page 11: Wall Or Solid Ceiling Mount Using Mount Plate

    4.2.1.1 Wall or Solid Ceiling Mount Using Mount Plate Using included screws, attach the mount plate to your mounting wall or ceiling. It is recommended that the CW9166D1-MR be mounted to a wall or solid ceiling using the mount plate for physical security reasons.
  • Page 12: Electrical Junction Box Mount Using Mount Plate

    4.2.1.2 Electrical Junction Box Mount Using Mount Plate The CW9166D1-MR can be mounted to a 4” square cable junction box, a 3.5 or 4” round cable junction box, or various U.S. and European outlet boxes (mounting screws are not included). Using appropriate mounting hardware for your specific type of junction box, attach the mount 4.2.2 Power the CW9166D1-MR If mounting to an electrical junction box, feed the Ethernet cable through the cable access hole in the Mount...
  • Page 13: Powering The Cw9166D1-Mr With Meraki Ac Adapter

    4.2.2.1 Powering the CW9166D1-MR with the Meraki AC Adapter (sold separately) 1. Plug the power cord into the CW9166D1-MR and the other end into a wall outlet. 2. Plug an Ethernet cable that is connected to an active Ethernet connection into the Eth0 port on the CW9166D1-MR.
  • Page 14: Powering The Cw9166D1-Mr With An 802.3At Power Over Ethernet Switch

    4.2.2.3 Powering the CW9166D1-MR with an 802.3at Power over Ethernet Switch Route Ethernet cable from a port on an active 802.3at PoE switch to the Eth0 port in the bay of the CW9166D1-MR. The CW91661-MR is Gigabit Ethernet-capable. To maximize device performance, a Gigabit-capable switch should be used.
  • Page 15: Assemble Cw9166D1-Mr To The Mount Plate

    4.2.3.2 Assemble CW9166D1-MR to the Mount Plate (This section applies to wall and/or solid ceiling, drop ceiling or electrical junction box mount where you have already installed the mount plate.) Insert the top latch on the mount plate into the top mount plate attachment slots on the back of the device. Rotate the bottom of the unit into the bottom mount plate attachment slot.
  • Page 16: Desk Or Shelf Mount

    4.2.3.3 Desk or Shelf Mount The CW9166D1-MR can be placed on a desk or shelf resting on the non-scratch rubber feet. The mount plate is not necessary for a desk or shelf mounting.
  • Page 17: Secure The Cw9166D1-Mr

    4.3 Secure the CW9166D1-MR Depending on your mounting environment, you may want to secure the CW9166D1-MR to its mount location. Your CW9166D1-MR can be secured in several ways. If the CW9166D1-MR has been installed using the mount plate, it can be secured via security screw (Torx and Philips head security screws are included;...
  • Page 18: Verify Device Functionality And Test Network Coverage

    4.4 Verify Device Functionality and Test Network Coverage 1. Check LEDs The LED should be solid white. If it is flashing orange, the firmware is automatically upgrading and the LED should turn green when the upgrade is completed (normally in under thirty minutes). Note: Your CW9166D1-MR must have an active route to the Internet to check and upgrade its firmware.
  • Page 19 IEEE 802.11b or 802.11g operation of this product in the USA is firmware-limited to channels 1 through 11. FCC regulations restrict the operation of this device to indoor use only. The operation of this device is prohibited on oil platforms, cars, trains, boats, and aircraft, except that operation of this device is permitted in large aircraft while flying above 10,000 feet.
  • Page 20 If the device is going to be operated in the 5.15 - 5.25 G H z frequency range, then it is restricted to indoor environment only. This device meets all other requirements specified in Part 15E, Section 15.407 of the FCC Rules. Industry Canada Statement HVIN: CW9166D1-MR V01 This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and...
  • Page 21 Operation shall be limited to indoor use only. Utilisation limitée à l’intérieur seulement. Devices shall not be used for control of or communications with unmanned aircraft systems. Les appareils ne doivent pas être utilisés pour contrôler ou communiquer avec des systèmes d'aéronefs sans pilote.
  • Page 22 UK:The device is restricted to indoor use only when operating in the 5150 to 5350 MHz, 5925 to 6425MHz frequency range. Hereby, Cisco Systems Inc. declares that the radio equipment type CW9166D1 series is in compliance with Directive 2014/53/EU and Radio Equipment Regulations 2017.