Download Print this page

JRC JAN-9201S Instruction Manual page 155

Hide thumbs Also See for JAN-9201S:

Advertisement

Message
Anemometer(Communic
ation failed, Main LAN)
Anemometer(Communic
ation failed, Sub LAN)
Autopilot(Communicatio
n Failed, Main LAN)
Autopilot(Communicatio
n Failed, Sub LAN)
Azimuth Thruster
#n(invalid)
Azimuth Thruster #n(not
plausible)
Azimuth Thruster
#n(unavailable)
BNWAS(Communication
failed, Main LAN)
BNWAS(Communication
failed, Sub LAN)
Bow Azimuth Thruster
#n (invalid)
Explanation
Communication with
Anemometer cannot be
performed via Main LAN.
Communication with
Anemometer cannot be
performed via Sub LAN.
Communication with
Autopilot cannot be
performed via Main LAN.
Communication with
Autopilot cannot be
performed via Sub LAN.
There is a format error or
a status error of the data.
There is a range error of
the data.
The data cannot be
received.
Communication with
BNWAS cannot be
performed via Main LAN.
Communication with
BNWAS cannot be
performed via Sub LAN.
There is a format error or
a status error of the data.
A-17
Advice
Check the condition of Anemometer and Main
LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Check the condition of Anemometer and Sub
LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
"Check the condition of Autopilot and Main
LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor."
"Check the condition of Autopilot and Sub
LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor."
Check the sensor condition.
Check the sensor condition.
Check the condition of the sensor and the
communication path.
"Check the condition of BNWAS and Main
LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor."
"Check the condition of BNWAS and Sub
LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor."
Check the sensor condition.
APP A
Appendix A Alert List
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25

Advertisement

loading

This manual is also suitable for:

Jan-7201s