VERTICAL, 90-DEGREE ELBOW TO HORIZONTAL OUT THE
WALL (12" minimum rise before elbow)
Dimensions (in inches)
A
B
9
14 to 15-1/2
12
17 to 18-1/2
18
20 to 21-1/2
CORNER INSTALLATION - VERTICAL, 90-DEGREE ELBOW TO
HORIZONTAL OUT THE WALL (12" minimum rise before elbow)
DIMENSIONS (in inches)
Dim.
DVCX36
A
47
B
33-1/4
C
13-3/4
D
66-3/8
39634-2-0720
INSTALLATION (CONT'D)
C
4-3/4 to 6-1/4
4-3/4 to 9-1/4
10-3/4 to 12-1/4
Figure 26
DVCX42
49-7/8
35-1/4
15-1/8
70-1/2
Figure 27
After installing the vent system, install flue heat shield.
1. Hand bend tabs on flue heat shield out 90°.
2.
Attach to insulation box as shown in Figure 26.
Figure 28 (vent pipe removed for clarity)