Toshiba BA400 Series Key Operation Specification page 26

Hide thumbs Also See for BA400 Series:
Table of Contents

Advertisement

to the threshold fine adjustment screen and pressing the [RIGHT] key shows the details of the result.
(10) During a threshold setting, the media is fed at the same speed with that for the previous issue.
(11) Whether the threshold setting succeeded or not can be checked with the following methods.
 Media feed with the [FEED] key
1) While the judgment result is displayed, press the [FEED] key to terminate the threshold setting.
→ The printer is placed in the pause state.
2) Press the [RESTART] key to clear the pause state.
→ The printer is placed in the online state.
3) Hold down the [FEED] or [RESTART] key
→ The printer enters the system mode.
4) Select "<4>SENSOR" and "THRESHOLD SELECT".
5) Select the applicable media sensor type ("REFLECT" or "TRANS.") and press the [PAUSE] key.
→ The selected sensor type menu is shown.
6) Select "MANUAL THRESHOLD", press the [PAUSE] key.
→ The system mode menu is displayed.
7) Turn off the power, and back to on.
→ The printer is placed in the online state.
8) Press the [FEED] key to feed the media.
→ If a paper jam occurs or the media does not stop at the print start position, retry the threshold setting.
 Sending Issue command
1) While the judgment result is displayed, press the [FEED] key to terminate the threshold setting.
→ The printer is placed in the pause state.
2) Press the [RESTART] key to clear the pause state.
→ The printer is placed in the online state.
3) Hold down the [FEED] or [RESTART] key.
→ The printer enters the system mode.
4) Select "<4>SENSOR" and "THRESHOLD SELECT".
5) Select the same media sensor type with that specified by the Issue Command which is sent to the printer.
Sensor type in Issue Command
0: No sensor
1: Reflective sensor
2: Transmissive sensor (when using
normal labels)
3: Transmissive sensor (when using
preprinted labels)
Setting
Whether the threshold setting succeeded or not cannot be
checked.
Select "<4>SENSOR", "THRESHOLD SELECT" with the
[PAUSE] keys.
Select "REFLECT".
When the selected sensor type display is shown, select
"MANUAL THRESHOLD" and press the [PAUSE] key.
* Select the media sensor type to the one for which the
threshold was set.
Select "TRANS."
When the selected sensor type display is shown, select
"MANUAL THRESHOLD" and press the [PAUSE] key.
* Select the media sensor type to the one for which the
threshold was set.
No setting is necessary.
25