SYSTEM ASSEMBLY
WATER CONNECTIONS END – EXPLODED VIEW
PREASSEMBLY NOTES
These solar collectors have passed the AS/NZS 2712 requirements for resistance to hailstone damage,
so it is not normally necessary to fit a guard to a collector. Stone Guards are available to provide a level
of protection to the collectors against vandalism or accidental damage. Contact Rheem or your local
Rheem Solar Water Heater Distributor for details.
The Rheem warranty DOES NOT cover breakage of solar collector glass. Check your insurance policy
covers collector glass breakage.
Warning: No attempt should be made to remove or replace broken collector glass.
The collector glass is not offered as a replacement part. Should the solar collector require replacement,
contact Rheem or your local Rheem Solar Water Heater Distributor for details.
Warning: Do not remove the solar collector packaging completely, prior to the installation as the solar
collector surface can become very hot. Remove only sufficient packaging material to enable the
installation of the solar collectors.
Upon completion of the installation of the solar water heater the packaging material may be removed from
the NPT 200 solar collectors, whether or not the solar water heater is commissioned.
The solar collector packaging must be removed completely prior to the permanent operation of the water
heater.
All connectors, end plugs, O'rings, brass fittings, roof straps, and collector rail required for the installation
are included with the pipe kit.
Suitable screws or anchors will be required to fix the roof straps to the rafters for a pitched roof installation.
Warning: Where roof straps, frames, etc. are secured to roof members, all fixings must be of an
appropriate type to suit the type of member. Inadequate or inappropriate fixings may result in the roof
straps becoming unsecured and the installation of the solar hot water system becoming unsafe.
If the solar storage tank is being installed with existing solar collectors, then utilise the existing fittings and
pipes used on the installation. A new temperature pressure relief valve and expansion control valve must
be installed. These valves are not supplied with the tank.
Note: Component (20), adaptor
M33 F x 3/4 M is supplied fitted to
the solar storage tank.