Resetting to Factory Default Values

All user options for the H4TU-C-388 List 1
MODE and SEL pushbuttons. To set the user options to their default values:
1
Press the SEL pushbutton for 6 seconds until the following message appears:
DFLT NO
2
Press the SEL pushbutton while the DFLT NO message is displayed.
The message changes to DFLT YES indicating the factory default values are now in effect and the display
returns to the normal mode.
To terminate the DFLT mode without setting the factory default values, do one of the following:
Press the MODE pushbutton to return to the normal display mode.
Wait 30 seconds for the unit to return to the normal display mode.

Displaying System Parameter Settings

To scroll through the current settings of all system parameters, press the MODE pushbutton for 3 or more seconds.
The H4TU-C-388 List 1 displays the following parameters:
Software version number
List number
Type of frame pattern received from the DSX-1
Line code of the signal received from the DSX-1
All user-configured parameter settings
Loop attenuation threshold setting
Margin alarm threshold setting

Disabling an Alarm

System alarms can be disabled by pressing the SEL pushbutton on the H4TU-C-388 List 1 front panel for less than
3 seconds. This executes an ACO and returns the H4TU-C-388 List 1 to its non-alarm state. For more information
about alarms, see
"System Alarms" on page

Loopback Modes

See
"Loopback Operation" on page 47
loopbacks.
H4TU-C-388 List 1
(Table 6 on page
20) can be set to the factory default values using the
43.
for instructions on using the MODE and SEL pushbuttons to activate