Download Print this page

Mechanical Installation - YASKAWA CIMR-AC4A0103TAA Quick Start Manual

Ac drive a1000

Advertisement

2

Mechanical Installation

Upon Receipt
Perform the following tasks after receiving the drive:
• Inspect the drive for damage. If the drive appears damaged upon receipt, contact your supplier.
• Verify receipt of the correct model by checking the information on the nameplate. If you have received the wrong
model, contact your supplier.
Installation Environment
For optimum performance life of the drive, install the drive in an environment that meets the conditions listed below.
Environment
Installation Area
Ambient Temperature
Humidity
Storage Temperature
Surrounding Area
Altitude
Vibration
Orientation
Installation Orientation and Spacing
Always install the drive in an upright position. Leave space around the unit for proper cooling as shown in the figure
below.
YASKAWA Europe TOEP C710606 96A - AC Drive A1000 IP54 Wallmount - Quick Start Guide
Indoors.
-10°C to +40°C
Drive reliability improves in environments without wide temperature fluctuations.
95% RH or less and free of condensation
-20 to +60°C
Install the drive in an area free from:
• oil mist and dust
• metal shavings, oil, water or other foreign materials
• radioactive materials
• combustible materials (e.g., wood)
• harmful gases and liquids
• excessive vibration
• chlorides
• direct sunlight
1000 m, up to 3000 m with derating (for details, refer to the Technical Manual)
10 to 20 Hz at 9.8 m/s
2
20 to 55 Hz at 5.9 m/s
2
Install the drive vertically to maintain maximum cooling effects.
30mm
Conditions
30mm
100mm
Air
100mm
Air
2 Mechanical Installation
EN 9

Advertisement

loading