Pioneer PDP-507XC Service Manual page 283

Table of Contents

Advertisement

1
< No. 2 Subcategory Information on "Failure in IIC communication of Main microcomputer" >
Value
0
Non subcategory
A
1
Analog tuner1 (Front end 1)
3
MPX
4
AV switch
5
RGB switch
8
Main VDEC
9
Sub VDEC
A
AD/PLL
B
HDMI
E
M2 communication
B
F
M2 busy
G
64k EEPROM
H
AUDIO IC
< No. 3 Subcategory Information on "Digital tuner" >
Value
0
Non subcategory
1
DTV starting failure
2
DTV communication failure
C
< No. 4 Subcategory Information on "POWER" >
Value
1
DCDC Converter heden
2
Relay Power supply heden
D
9.3.12 DRV
Drive ON/OFF: ON/OFF control for only the large-power system
Command
Effective Operation
Format
E
[DRV+S00]
Every time
[DRV+S01]
Every time
F
174
1
2
Shutdown Factor
Shutdown Factor
Shutdown Factor
Modes
DRIVE OFF
DRIVE ON
2
3
Remarks (Operation)
FE1 (immediately Power Supply OFF)
MPX (After 3 times reset action, turn Power Supply off (except for us))
AV-SW (immediately Power Supply OFF)
RGB-SW (immediately Power Supply OFF)
M-VDEC (immediately Power Supply OFF)
S-VDEC (immediately Power Supply OFF)
ADC (immediately Power Supply OFF)
HDMI (immediately Power Supply OFF)
TX-COM (After 3 times reset action, turn Power Supply off)
TX-BSY (After 3 times reset action, turn Power Supply off)
MA-EEP (immediately Power Supply OFF)
Remarks (Operation)
PS/RST (The history is left, and intercepts it the communication)
RETRY (The history is left, and intercepts it the communication)
Remarks (Operation)
M-DCDC (immediately Power Supply OFF)
RELAY (immediately Power Supply OFF)
Function
At standby mode, when 10 seconds passed after
issuing [DRV+S00], command becomes invalid.
PDP-507XD
3
4
Remarks
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pdp- 507xgPdp- 507xda