6. RS-232C

6.1 OUTLINE OF RS-232C COMMAND

A

6.1.2 USING RS-232C COMMANDS

For the PDP-507XC, PDP-507XG and PDP-507XDA series Plasma Displays, the circuitry is structured as shown in the
diagram below to support the SR+ system. Controlling with either the SR+ system or RS-232C commands can be selected.
As the SR+ system is selected at shipment, to control with RS-232C commands in servicing it is necessary to switch the
paths. After servicing, be sure to return the setting to the SR+ system.
7 Rough diagram of switching between SR+ and RS-232C
MAIN Assy
SR BLOCK
B
232C (DSUB_9P)
SR+ (SR out)
7 How to switch SR+/RS-232C ?
There are "How to switch SR+/RS-232C by remote control in the Standby Mode" and "How to switch SR+/RS-232C by
C
remote control in the INTEGRATOR MENU" as a Method
1 To select SR+/RS-232C by remote control in Standby Mode.
• During Standby mode, hold the keys other than the [POWER] key on the remote control, the following operation is
done within 10 seconds.
To select from SR+ to RS-232C/To select from RS-232C to SR+.
• During standby mode, hold the [VOLUME+ (or -)] key on the remote control unit pressed for 3 to 10 seconds.
→Then within 3 seconds after the key is released, hold the [2-screen] key released, use the [SET (ENTER)] key on
the remote control unit to set to RS-232C (the baud rate last selected is chosen) or the [HOME MENU] key to set to
SR+.
• During IF Standby mode (once 10 seconds or more has passed after the LED goes dark during communication), the
first keypress may not be accepted. In such a case, for a key operation, first press any key other than the [POWER]
key and [CH] keys, then the desired key.
D
• At the switch SR+/RS-232C, the LED will be blinked on the fixed time.
2 To select SR+/RS-232C in the INTEGRATOR MENU.
• How to enter INTEGRATOR MENU.
During standby mode, press the [Home Menu] key, and then press the [POWER] key within 3 seconds. During
factory mode, hold the [INTEGRATOR] key.
• In INTEGRATOR MENU, there is a OSD where SR+ (or RS-232C) is turned on/off, and it switches on the screen.
E
F
28
1
2
232C
TXD (EXT), RXD (EXT)
Driver
SR_EN_B
SR+
Interface
1
5
10
15
1
I
N T
E G
R
A
T O R
M E N U
5
10
15
S
R +
16
PDP-507XC
2
3
IF UCOM BLOCK
IC8301
(IF UCOM)
20
25
30
35
< = >
N
O
3
4
40
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pdp- 507xgPdp- 507xda

Table of Contents