Pioneer PDP-507XC Service Manual page 280

Table of Contents

Advertisement

5
9.3.8 QSD
The command QSD is for acquiring the data from the 8 latest shutdown (SD) logs.
Command
Effective Operation
Format
Modes
[QSD]
All operations
Data Arrangement
ECO
1
Latest SD data
2
Latest SD subcategory data
3
Data from the hour meter for the latest SD
4
Second latest SD data
5
Second latest SD subcategory data
6
Data from the hour meter for the second latest SD
7
Third latest SD data
8
Third latest SD subcategory data
9
Data from the hour meter for the third latest SD
10
Fourth latest SD data
11
Fourth latest SD subcategory data
12
Data from the hour meter for the fourth latest SD
13
Fifth latest SD data
14
Fifth latest SD subcategory data
15
Data from the hour meter for the fifth latest SD
16
Sixth latest SD data
17
Sixth latest SD subcategory data
18
Data from the hour meter for the sixth latest SD
19
Seventh latest SD data
20
Seventh latest SD subcategory data
21
Data from the hour meter for the seventh latest SD
22
Eighth latest SD data
23
Eighth latest SD subcategory data
24
Data from the hour meter for the eighth latest SD
CS
5
6
Function
To acquire data on the shutdown logs
Data
Length Output Example
3 byte
1 byte
1 byte
8 byte
00752013
1 byte
1 byte
8 byte
00495204
1 byte
1 byte
8 byte
00100355
1 byte
1 byte
8 byte
00075620
1 byte
1 byte
8 byte
00000852
1 byte
1 byte
8 byte
000000451
1 byte
1 byte
8 byte
00000000
1 byte
1 byte
8 byte
00000000
2 Byte
PDP-507XD
6
7
Remarks
Return data: 3 (ECO)+80(DATA)+2(CS)= 85 Byte
¶ SD data
0
No SD
QSD
1
SQ-IC
1
2
MDU-IIC
0
3
RST2
4
TEMP
5
¶ SD subcategory (SQ-IC)
0
0
No SD-Sub data
2
1
Communication error
3
2
Drive stop
3
BUSY
6
Version mismatching
2
5
1
0
¶ SD subcategory (MDU-IIC)
2
0
No SD-Sub data
5
1
EEPROM
2
BACKUP
0
3
DAC
0
¶ SD subcategory (TEMP)
0
0
No SD-Sub data
0
1
TEMP1
2
Reserved
7D
7
8
A
B
C
D
E
F
171
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pdp- 507xgPdp- 507xda