Some Part Of Air Conditioner Does Not Operate - Sanyo SAP-K181GJH Technical & Service Manual

Indoor/outdoor units
Table of Contents

Advertisement

9-3. Some part of air conditioner does not operate.

9-3-1. Only indoor fan does not run.
• Check fan rotation.
Turn fan gently once or twice by
hand.
• Measure resistance of indoor fan
motor winding.
• Check fan motor capacitor.
9-3-2. Only flap motor does not run.
• Measure resistance of flap motor
winding.
9-3-3. Function of outdoor fan speed control does not work properly.
• Check thermostat in outdoor unit.
Refer to "8-8 Outdoor Fan Speed Control".
Fan cannot
be turned.
OK
(23S)
• Check fan casing
foreign matter on
inside.
Fan motor burnout
or foreign matter in
bearings.
40
Remove foreign
matter or repair.
Repair or replace.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sap-k241gjhSap-c181ghSap-c241gh

Table of Contents