Outdoor Fan Speed Control - Sanyo SAP-K181GJH Technical & Service Manual

Indoor/outdoor units
Table of Contents

Advertisement

Defrosting Mode Timing Chart
Compressor
Outdoor fan
Solenoid coil
(4–way valve)
Indoor fan
Standby lamp
Indoor heat
exch. coil
temp.
35° C
NOTE
*1: Refer to "8-6 Cold Draft Prevention".
8-8. Outdoor Fan Speed Control (Cooling and Dry Operation)
To optimize performance of the air conditioner, the outdoor fan speed is switched automatically according to the
outdoor temperature.
If the outdoor air temperature falls below 28.5°C, the fan speed switches to LOW.
If the outdoor air temperature rises above 31.5°C, the fan speed switches to HIGH.
This function does not become active in heating operation.
Outdoor air
temperature (°C)
Outdoor fan
speed
Start of defrosting
32 seconds
ON
OFF
ON
2 seconds
ON
Set speed
OFF
31.5
28.5
H
11 minutes
32 seconds
ON
ON
OFF
OFF
ON
L
34
Release of defrosting
OFF
ON
ON
2 seconds
ON
Set speed
ON
Release of
cold draft prevention
H
OFF
* 1

Advertisement