1.2 Risk Group 3 Safety

1.2.1 General considerations

Notice on optical radiation from G50 Projector when it becomes Risk Group 3
For RG3, no direct exposure to the beam shall be permitted.
For RG3, operators shall control access to the beam within the hazard distance or install the product at a
height that will prevent eye exposure within the hazard distance.
This projector has one or several built-in Class 4 laser clusters. Disassembly or modification is very
dangerous and should never be attempted.
Any operation or adjustment not specifically instructed by the user's guide creates the risk of hazardous
laser radiation exposure.
Do not open or disassemble the projector as this may cause damage by the exposure of laser radiation.
FOR PROFESSIONAL USE ONLY means installation can only be carried out by Barco AUTHORIZED
PERSONNEL familiar with potential hazards associated with high intensity light beams.
WARNING: No direct exposure to the beam within the hazard distance shall be permitted, RG3
(Risk Group 3) IEC EN 62471-5:2015
CAUTION: Use of controls or adjustments or performance of procedures other than those specified
herein may result in hazardous radiation exposure.
PPE (Personal Protective Equipment) description
A skilled person or service person shall be worn protective clothes and goggles when access to restricted
area.
Possible skin or eye damage.
Disconnect power before servicing.

1.2.2 High Brightness precautions: Hazard Distance

HD
Hazard Distance (HD) is the distance measured from the projection lens at which the intensity or the
energy per surface unit becomes lower than the applicable exposure limit on the cornea or on the
skin. The light beam is considered (to be) unsafe for exposure if the distance from a person to the
light source is less than the HD.
Restriction Zone (RZ) based on the HD
The HD depends on the amount of lumens produced by the projector and the type of lens installed. See
chapter
"General considerations", page
To protect untrained end users (as cinema visitors, spectators) the installation shall comply with the following
installation requirements: Operators shall control access to the beam within the hazard distance or install the
product at a height that will prevent spectators' eyes from being in the hazard distance. Radiation levels in
excess of the limits will not be permitted at any point less than 2.0 meter (SH) above any surface upon which
persons other than operators, performers, or employees are permitted to stand or less than 1.0 meter (SW)
lateral separation from any place where such persons are permitted to be. In environments where
unrestrained behavior is reasonably foreseeable, the minimum separation height should be greater than or
equal to 3.0 meter to prevent potential exposure, for example by an individual sitting on another individual's
shoulders, within the HD.
These values are minimum values and are based on the guidance provided in IEC 62471-5:2015 section
6.6.3.5.
The installer and user must understand the risk and apply protective measures based upon the hazard
distance as indicated on the label and in the user information. Installation method, separation height, barriers,
detection system or other applicable control measure shall prevent hazardous eye access to the radiation