Electrical Connection Directions

Connection Step 1
Connect the power vent module to the connection box labelled POWER
VENT CONNECTION (second box from the top of the panel's left side).
This is a three phase system that requires the installer to supply three
hot wires and ground from the control panel to the power vent module.
Connection Step 2
The control panel is supplied with 25 feet of 18 AWG/2 conductor low
voltage wire that is coiled up on the side of the control panel. Connect
these wires to a standard single pole wall switch. Do not apply any
power to these wires. This wire may be replaced with a longer wire of
the same gauge, type, and quality to a length of up to 150 feet.
Connection Step 3
Connect power to the wires in the connection box labeled POWER
SUPPLY 208V, 15 AMP (first box from the top of the panel's left side).
This is a four wire system with two blacks (L1 and L2), white (neutral),
and green (ground).
Connection Step 4
Connect 120V power to the base of the fireplace to power the LED
lighting inside the unit. This is a two wire connection consisting of a
black (hot) and white (neutral) wire.
CAUTION
Connecting power to the panel before all the wiring is connected may
damage the panel.
CAUTION
Incorrect wiring may damage the motor and the fireplace will not
function properly.
XG0799 - 081319
CAUTION
Incorrect wiring may damage the motor and the fireplace will not
function properly.
Damper connections (if applicable)
Wire colors from motor to damper wire terminal block may differ
based on damper size
Connection Step 1
Open up the damper connection box on the side of the control panel
to access the 5 wires for damper control. Connect all 5 wires with the
matching colors from the damper cable.
Connection Step 2
The white and black wires supply 24 VAC to the damper motor. Connect
the black damper wire to the black connection box wire, and the white
damper wire to the white connection box wire. For multiple dampers,
connect power in parallel.
White
Black
Single Damper Motor
The white and black wires are for
the damper motors and should be
matched for colour.
The red and brown wires connect to an end switch that will close
when the damper has opened. Connect the brown damper wire to the
connection box brown wire, and the red damper wire to the connection
box red wire. For multiple dampers, connect the end switches in series.
Red to brown, to red to brown.
The green wire is a ground connection and is used to bond the damper
cable to the control panel.
Red
Brown
Single End Switch
The red and brown wires are the
end switch wires. If there is only
one end switch, the wires should
be matched red to red and brown
to brown.
Installation
White
Black
Multiple Damper Motors
For multiple damper motors,
connect them in parallel; all white
wires together and all black wires
together.
Red
Brown
Brown
Red
Brown
Red
Damper 1
Damper 2
Damper 3
Multiple End Switches
The red and brown wires are
the end switch wires. If there are
multiple end switches, they need to
be run in series with one another
between the connection box red
and brown wires.