In-Line Mounted - Montigo PCPR8 Installation & Maintenance Manual

Indoor gas fireplace
Table of Contents

Advertisement

In-Line Mounted

Positive
pressure
rated pipe
Power
vent
B or C
Vent
B or C
Vent
*NEVER INSTALL THE MOTOR WITH ITS SHAFT VERTICALLY, THE MOTOR
AXIS MUST BE HORIZONTAL
** ENSURE ACCESS DOOR CAN OPEN AT LEAST 80 DEGREES
MODEL SIZE
3'
'A'
7 7/8"
CAUTION
Never install the Power Vent motor pointing up or down.
The Power Vent motor must always be installed in the horizontal
plane. Additionally the Power Vent must be securely mounted in a
manner which also allows the possibility for the access door to be
opened. The Motor/Access Door must have at least 12" of additional
clearance to be able to pull out the Motor/Access Door/Fan Wheel
assembly for servicing. -The structure which the Power Vent is
mounted to must be Non-Combustible Material Only.
XG0799 - 081319
Power supply wire
Single Phase 200–
240VAC + Neutral, 15
A, dedicated circuit
Power vent wire
B Vent
Control
cable 9
wire
LED Power
120V, 2A
4'
5'
6'
7'
9 7/8"
9 7/8"
9 7/8"
9 7/8"
1313/16"
Control
11"
Panel
Wall
switch
8'
11 7/8"
Installation
91/16"
A
171/16"
47/8"
16"
81/2"
117/8"
193/8"
85/8"
23716"
7"
14"
11

Advertisement